Mucin balls with wear of conventional and silicone hydrogel contact lenses
- PMID: 12692485
- DOI: 10.1097/00006324-200304000-00006
Mucin balls with wear of conventional and silicone hydrogel contact lenses
Abstract
Purpose: To compare the frequency of mucin balls in subjects wearing conventional and high-Dk silicone hydrogel lenses during 12 months of extended-wear and to determine whether mucin balls are associated with any lens or subject characteristics.
Methods: This study used data from a clinical trial where subjects wore either conventional hydrogel (N = 69, 6-night extended-wear) or silicone hydrogel (N = 70, 30-night extended-wear) contact lenses for 12 months. The number of mucin balls and other physiological responses, lens fit and performance, and subjective patient responses to lens wear were rated at each scheduled visit.
Results: Subjects in the silicone hydrogel group had significantly greater numbers of mucin balls compared with subjects in the conventional hydrogel group over time (p < 0.001), but there were no significant differences in the percentage of subjects with mucin balls between the two groups. Increasing lens wettability, back surface deposits, and time of lens wear were associated with higher numbers of mucin balls in the conventional hydrogel group (p < 0.05); steeper corneal curvature and increasing lens wettability, back surface deposits, and number of microcysts were associated with higher numbers of mucin balls in the silicone hydrogel group (p < 0.05).
Conclusions: This study indicates that a subset of the population is predisposed to develop mucin balls irrespective of the soft contact lens type worn, but lens type influences the degree of mucin ball formation. The relationship between lens wettability, back surface deposits, and steeper corneal curvature with mucin balls supports the hypothesis that the mechanical interaction of a lens with the surface layer of the epithelium and the tear film in association with the blinking forces of the lid is involved in mucin ball formation.
Similar articles
-
Clinical characterization of spherical post-lens debris associated with lotrafilcon high-Dk silicone lenses.CLAO J. 2000 Oct;26(4):186-92. CLAO J. 2000. PMID: 11071342
-
Epithelial inclusions in association with mucin ball development in high-oxygen permeability hydrogel lenses.Optom Vis Sci. 2000 Feb;77(2):68-72. doi: 10.1097/00006324-200002000-00010. Optom Vis Sci. 2000. PMID: 10701804
-
A 1-year prospective clinical trial of balafilcon a (PureVision) silicone-hydrogel contact lenses used on a 30-day continuous wear schedule.Ophthalmology. 2002 Jun;109(6):1172-7. doi: 10.1016/s0161-6420(02)01045-x. Ophthalmology. 2002. PMID: 12045062 Clinical Trial.
-
Silicone hydrogel contact lenses and the ocular surface.Ocul Surf. 2006 Jan;4(1):24-43. doi: 10.1016/s1542-0124(12)70262-8. Ocul Surf. 2006. PMID: 16669523 Review.
-
Risk of corneal inflammatory events with silicone hydrogel and low dk hydrogel extended contact lens wear: a meta-analysis.Optom Vis Sci. 2007 Apr;84(4):247-56. doi: 10.1097/OPX.0b013e3180421c47. Optom Vis Sci. 2007. PMID: 17435508 Review.
Cited by
-
Adverse events in allergy sufferers wearing contact lenses.Postepy Dermatol Alergol. 2015 Jun;32(3):204-9. doi: 10.5114/pdia.2015.48071. Epub 2015 Jun 15. Postepy Dermatol Alergol. 2015. PMID: 26161062 Free PMC article. Review.
-
A case of atypical mucin balls wearing extended wear of silicone hydrogel lens for therapeutic use.Case Rep Ophthalmol Med. 2013;2013:167854. doi: 10.1155/2013/167854. Epub 2013 Apr 27. Case Rep Ophthalmol Med. 2013. PMID: 23710394 Free PMC article.
-
Biopolymeric Mucin and Synthetic Polymer Analogs: Their Structure, Function and Role in Biomedical Applications.Polymers (Basel). 2016 Mar 2;8(3):71. doi: 10.3390/polym8030071. Polymers (Basel). 2016. PMID: 30979166 Free PMC article. Review.
-
The association between mucin balls and corneal infiltrative events during extended contact lens wear.Cornea. 2011 May;30(5):535-42. doi: 10.1097/ICO.0b013e3181fb8644. Cornea. 2011. PMID: 21173699 Free PMC article.
-
Tear exchange and contact lenses: a review.J Optom. 2015 Jan-Mar;8(1):2-11. doi: 10.1016/j.optom.2014.12.001. Epub 2015 Jan 7. J Optom. 2015. PMID: 25575892 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical