Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery
- PMID: 12693996
- DOI: 10.1046/j.1365-2044.2003.03091.x
Evaluation of oesophageal pulse oximetry in patients undergoing cardiothoracic surgery
Abstract
Pulse oximetry probes placed peripherally may fail to give accurate values of blood oxygen saturation when the peripheral circulation is poor. Because central blood flow may be preferentially preserved, we investigated the oesophagus as an alternative monitoring site. A reflectance blood oxygen saturation probe was developed and evaluated in 49 patients undergoing cardiothoracic surgery. The oesophageal pulse oximeter results were in good agreement with oxygen saturation measurements obtained by a blood gas analyser, a CO-oximeter and a commercial finger pulse oximeter. The median (IQR [range]) difference between the oesophageal oxygen saturation results and those from blood gas analysis were 0.00 (-0.30 to 0.30 [-4.47 to 2.60]), and between the oesophageal oxygen saturation results and those from CO-oximetry were 0.75 (0.30 to 1.20 [-1.80 to 1.80]). Bland-Altman analysis showed that the bias and the limits of agreement between the oesophageal and finger pulse oximeters were -0.3% and -3.3 to 2.7%, respectively. In five (10.2%) patients, the finger pulse oximeter failed for at least 10 min, whereas the oesophageal readings remained reliable. The results suggest that the oesophagus may be used as an alternative monitoring site for pulse oximetry even in patients with compromised peripheral perfusion.
Similar articles
-
Investigation of oesophageal photoplethysmographic signals and blood oxygen saturation measurements in cardiothoracic surgery patients.Physiol Meas. 2002 Aug;23(3):533-45. doi: 10.1088/0967-3334/23/3/305. Physiol Meas. 2002. PMID: 12214761
-
Esophageal pulse oximetry utilizing reflectance photoplethysmography.IEEE Trans Biomed Eng. 2002 Nov;49(11):1360-8. doi: 10.1109/TBME.2002.804584. IEEE Trans Biomed Eng. 2002. PMID: 12450366
-
Evaluation of oesophageal reflectance pulse oximetry in major burns patients.Burns. 2005 May;31(3):337-41. doi: 10.1016/j.burns.2004.10.025. Epub 2005 Jan 20. Burns. 2005. PMID: 15774290
-
Pulse oximetry in the oesophagus.Physiol Meas. 2006 Jan;27(1):R1-35. doi: 10.1088/0967-3334/27/1/R01. Epub 2005 Nov 29. Physiol Meas. 2006. PMID: 16365505 Review.
-
Retinal oximetry and systemic arterial oxygen levels.Acta Ophthalmol. 2018 Nov;96 Suppl A113:1-44. doi: 10.1111/aos.13932. Acta Ophthalmol. 2018. PMID: 30460761 Review.
Cited by
-
Measuring venous oxygenation using the photoplethysmograph waveform.J Clin Monit Comput. 2010 Aug;24(4):295-303. doi: 10.1007/s10877-010-9248-y. Epub 2010 Jul 20. J Clin Monit Comput. 2010. PMID: 20644985
-
Filtering techniques for the removal of ventilator artefact in oesophageal pulse oximetry.Med Biol Eng Comput. 2006 Aug;44(8):729-37. doi: 10.1007/s11517-006-0089-2. Epub 2006 Jul 21. Med Biol Eng Comput. 2006. PMID: 16937215
-
A comparison of response time to desaturation between tracheal oximetry and peripheral oximetry.J Clin Monit Comput. 2010 Apr;24(2):149-53. doi: 10.1007/s10877-010-9227-3. Epub 2010 Mar 12. J Clin Monit Comput. 2010. PMID: 20224879
-
Evaluation of finger and forehead pulse oximeters during mild hypothermic cardiopulmonary bypass.J Clin Monit Comput. 2007 Aug;21(4):249-52. doi: 10.1007/s10877-007-9081-0. Epub 2007 Jun 20. J Clin Monit Comput. 2007. PMID: 17578673
-
Esophageal pulse oximetry is more accurate and detects hypoxemia earlier than conventional pulse oximetry during general anesthesia.Front Med. 2012 Dec;6(4):406-10. doi: 10.1007/s11684-012-0217-3. Epub 2012 Oct 2. Front Med. 2012. PMID: 23054501
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical