Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 Apr 23;125(16):4882-93.
doi: 10.1021/ja0341687.

Porphyrin and tetrabenzoporphyrin dendrimers: tunable membrane-impermeable fluorescent pH nanosensors

Affiliations

Porphyrin and tetrabenzoporphyrin dendrimers: tunable membrane-impermeable fluorescent pH nanosensors

Olga Finikova et al. J Am Chem Soc. .

Abstract

The pH dependencies of the UV-vis and fluorescent spectra of new water-soluble dendritic porphyrins and tetrabenzoporphyrins were studied. Because of extended pi-conjugation and nonplanar distortion, the absorption and the emission bands of tetraaryltetrabenzoporphyrins (Ar(4)TBP) are red-shifted and do not overlap with those of regular tetraarylporphyrins (Ar(4)P). When encapsulated inside dendrimers with hydrophilic outer layers, Ar(4)Ps and Ar(4)TBPs become water soluble and can serve as pH indicators, with pK's adjustable by the peripheral charges on the dendrimers. Two new dendritic porphyrins, Gen 4 polyglutamic porphyrin dendrimer H(2)P-Glu(4)OH (1) with 64 peripheral carboxylates and Gen 1 poly(ester amide) Newkome-type tetrabenzoporphyrin dendrimer H(2)TBP-Nw(1)OH (2) with 36 peripheral carboxylates, were synthesized and characterized. The pK's of the encapsulated porphyrins (pK(H)()2(P)(-)(Glu)()4(OH) = 6.2 and pK(H)()2(TBP)(-)(Nw)()1(OH) = 6.3) were found to be strongly influenced by the dendrimers, revealing significant electrostatic shielding of the cores by the peripheral charges. The titration curves obtained by differential excitation using the mixtures of the dendrimers were shown to be identical to those determined for the dendrimers individually. Due to their peripheral carboxylates and nanometric molecular size, porphyrin dendrimers cannot penetrate through phospholipid membranes. Dendrimer 1 was captured inside phospholipid liposomes, which were suspended in a solution containing dendrimer 2. No response from 1 was detected upon pH changes in the bulk solution, while the response from 2 was predictably strong. When proton channels were created in the liposome walls, both compounds responded equally to the bulk pH changes. These results suggest that porphyrin dendrimers can be used as fluorescent pH indicators for proton gradient measurements.

PubMed Disclaimer

Publication types

LinkOut - more resources