Guidelines for the analysis of Bence Jones protein
- PMID: 12705344
- DOI: 10.1515/CCLM.2003.054
Guidelines for the analysis of Bence Jones protein
Abstract
The detection and quantification of monoclonal free light chains in urine (Bence Jones protein, BJP) are thorny issues for the laboratorian. Immunoelectrophoretic techniques (immunofixation) allow the characterization of the two pathognomonic features of light chains: monoclonality and absence of heavy chains. Immunochemical methods such as nephelometry and turbidimetry are widely used in clinical practice to exclude the presence of BJP. However, these methods are limited by several metabolic and analytical problems. The accuracy of quantitative immunochemical methods is hampered by the heterogeneous molecular forms (fragments and polymers) of BJP and by the lack of reference materials, and the precision of the methods in clinically relevant regions of the dynamic range is poorly defined. Immunoelectrophoretic methods, especially immunofixation, are recommended because of their ability to demonstrate monoclonality and the absence of heavy chains. Immunofixation is also considered the best method to document the disappearance of the monoclonal protein (complete remission). The physiology of immunoglobulins and the clinical relevance of BJP are illustrated in the two appendices to this paper.
Similar articles
-
Studies of Bence Jones proteins by immunonephelometry.Ann Clin Lab Sci. 1992 Mar-Apr;22(2):100-9. Ann Clin Lab Sci. 1992. PMID: 1562164
-
Monoclonal free light chains in urine and their significance in clinical diagnostics: are they really tumor markers?J Clin Lab Anal. 1990;4(6):443-8. doi: 10.1002/jcla.1860040610. J Clin Lab Anal. 1990. PMID: 2283564
-
A new concept for detection of Bence Jones proteinuria in patients with monoclonal gammopathy.Clin Lab. 2004;50(3-4):181-5. Clin Lab. 2004. PMID: 15074473
-
Monoclonal free light chain detection and quantification: Performances and limits of available laboratory assays.Clin Biochem. 2021 Sep;95:28-33. doi: 10.1016/j.clinbiochem.2021.05.006. Epub 2021 May 12. Clin Biochem. 2021. PMID: 33991536 Review.
-
[The significance of analysis and detection of Bence Jones protein in the urine in clinical laboratory diagnosis].Orv Hetil. 1989 Aug 27;130(35):1871-5. Orv Hetil. 1989. PMID: 2507996 Review. Hungarian.
Cited by
-
The use of immunoglobulin light chain assays in the diagnosis of paraprotein-related kidney disease.Kidney Int. 2015 Apr;87(4):692-7. doi: 10.1038/ki.2014.333. Epub 2014 Oct 8. Kidney Int. 2015. PMID: 25296094 Free PMC article. Review.
-
Comparison of Fully Automated and Semiautomated Systems for Protein Immunofixation Electrophoresis.J Clin Lab Anal. 2017 Mar;31(2):e22027. doi: 10.1002/jcla.22027. Epub 2016 Jul 18. J Clin Lab Anal. 2017. PMID: 27424526 Free PMC article.
-
Reporting of quantitative protein electrophoresis in Australia and New Zealand: a call for standardisation.Clin Biochem Rev. 2009 Aug;30(3):141-51. Clin Biochem Rev. 2009. PMID: 19841697 Free PMC article.
-
Comparison of 24-hour versus random urine samples for determination and quantification of Bence Jones protein in a South African population.Afr J Lab Med. 2021 Aug 4;10(1):1228. doi: 10.4102/ajlm.v10i1.1228. eCollection 2021. Afr J Lab Med. 2021. PMID: 34522630 Free PMC article.
-
Best practice in primary care pathology: review 1.J Clin Pathol. 2005 Oct;58(10):1016-24. doi: 10.1136/jcp.2004.025049. J Clin Pathol. 2005. PMID: 16189144 Free PMC article. Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources