The threshold for brain damage in rabbits induced by bursts of ultrasound in the presence of an ultrasound contrast agent (Optison)
- PMID: 12706199
- DOI: 10.1016/s0301-5629(02)00741-x
The threshold for brain damage in rabbits induced by bursts of ultrasound in the presence of an ultrasound contrast agent (Optison)
Abstract
The purpose of this study was to test the hypothesis that burst ultrasound (US) in the presence of a US contrast agent using parameters similar to those used in brain blood flow measurements causes tissue damage. The brains of 10 rabbits were sonicated in 3-8 locations with 1.5-MHz, 10- micro s bursts repeated at a frequency of 1 kHz at temporal peak acoustic pressure amplitudes ranging from 2 to 12.7 MPa. The total sonication time for each location was 20 s. Before each sonication, a bolus of US contrast agent was injected IV. Contrast-enhanced magnetic resonance (MR) images were obtained after the sonications to detect local enhancement in the brain. Whole brain histological evaluation was performed, and the sections were stained with hematoxylin and eosin (H and E), TUNEL, and vanadium acid fuchsin (VAF) staining to evaluate tissue effects, including apoptosis and ischemia. Both the magnetic resonance imaging (MRI) contrast enhancement and histology findings indicated that brain tissue damage was induced at a pressure amplitude level of 6.3 MPa. The damage included vascular wall damage, hemorrhage and, eventually, necrosis. Mild vascular damage was observed localized in a few microscopic tissue volumes in about half of the sonicated locations at all pressure values tested (down to 2 MPa). However, these sonications did not induce any detectable tissue effects, including ischemia or apoptosis. As a conclusion, the study showed that the US exposure levels currently used for blood flow measurements in brain are below the threshold of blood-brain barrier opening or brain tissue damage. However, one should be aware that brain damage can be induced if the exposure level is increased.
Similar articles
-
Local and reversible blood-brain barrier disruption by noninvasive focused ultrasound at frequencies suitable for trans-skull sonications.Neuroimage. 2005 Jan 1;24(1):12-20. doi: 10.1016/j.neuroimage.2004.06.046. Neuroimage. 2005. PMID: 15588592
-
MRI-guided targeted blood-brain barrier disruption with focused ultrasound: histological findings in rabbits.Ultrasound Med Biol. 2005 Nov;31(11):1527-37. doi: 10.1016/j.ultrasmedbio.2005.07.010. Ultrasound Med Biol. 2005. PMID: 16286030
-
Focal disruption of the blood-brain barrier due to 260-kHz ultrasound bursts: a method for molecular imaging and targeted drug delivery.J Neurosurg. 2006 Sep;105(3):445-54. doi: 10.3171/jns.2006.105.3.445. J Neurosurg. 2006. PMID: 16961141
-
Induction of apoptosis in vivo in the rabbit brain with focused ultrasound and Optison.Ultrasound Med Biol. 2006 Dec;32(12):1923-9. doi: 10.1016/j.ultrasmedbio.2006.06.026. Ultrasound Med Biol. 2006. PMID: 17169704
-
Ultrasound contrast agents: balancing safety versus efficacy.Expert Opin Drug Saf. 2009 Jan;8(1):49-56. doi: 10.1517/14740330802658581. Expert Opin Drug Saf. 2009. PMID: 19236217 Review.
Cited by
-
"Focused Ultrasound-mediated Drug Delivery in Humans - a Path Towards Translation in Neurodegenerative Diseases".Pharm Res. 2022 Mar;39(3):427-439. doi: 10.1007/s11095-022-03185-2. Epub 2022 Mar 7. Pharm Res. 2022. PMID: 35257286 Free PMC article. Review.
-
Noninvasive and localized blood-brain barrier disruption using focused ultrasound can be achieved at short pulse lengths and low pulse repetition frequencies.J Cereb Blood Flow Metab. 2011 Feb;31(2):725-37. doi: 10.1038/jcbfm.2010.155. Epub 2010 Sep 15. J Cereb Blood Flow Metab. 2011. PMID: 20842160 Free PMC article.
-
Thresholds for thermal damage to normal tissues: an update.Int J Hyperthermia. 2011;27(4):320-43. doi: 10.3109/02656736.2010.534527. Int J Hyperthermia. 2011. PMID: 21591897 Free PMC article. Review.
-
Feasibility of noninvasive cavitation-guided blood-brain barrier opening using focused ultrasound and microbubbles in nonhuman primates.Appl Phys Lett. 2011 Apr 18;98(16):163704. doi: 10.1063/1.3580763. Epub 2011 Apr 20. Appl Phys Lett. 2011. PMID: 21580802 Free PMC article.
-
Progress and problems in the application of focused ultrasound for blood-brain barrier disruption.Ultrasonics. 2008 Aug;48(4):279-96. doi: 10.1016/j.ultras.2008.04.004. Epub 2008 Apr 14. Ultrasonics. 2008. PMID: 18511095 Free PMC article. Review.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Research Materials