Evaluation of carotid stenosis by phonoangiography
- PMID: 127121
- DOI: 10.1056/NEJM197511272932205
Evaluation of carotid stenosis by phonoangiography
Abstract
Quantitative spectral (frequency) analyses were performed on 60 carotid bruits in 48 patients with suspected carotid stenosis. The technic was totally noninvasive. Bruits were recorded at the skin surface, analyzed by a minicomputer, and the degree of arterial stenosis estimated using a recently derived theory of sound production by turbulent blood flow. This method has been named phonoangiography. Fifty of the 60 bruits (83 per cent) had spectrums characteristic of turbulent blood flow, and a residual lumen diameter could be calculated. Results from the noninvasvie technic compared well with data obtained from radiographic carotid arteriograms in the 50 bruits with internal carotid artery stenosis. The residual lumen diameter estimated from phonoangiography differed from the radiographic value by less than 1 mm in 83 per cent and less than 1.5 mm in 92 per cent of the studies. Phonoangiography appears to be a useful method for assessment of carotid artery stenosis.
Similar articles
-
Correlation of spectral phonoangiography and carotid angiography with gross pathology in carotid stenosis.N Engl J Med. 1981 Aug 20;305(8):417-9. doi: 10.1056/NEJM198108203050801. N Engl J Med. 1981. PMID: 7254278
-
Quantitative carotid phonoangiography.Stroke. 1981 Nov-Dec;12(6):798-803. doi: 10.1161/01.str.12.6.798. Stroke. 1981. PMID: 7303070
-
Diagnosis of carotid stenosis by bruit spectral analysis.Am J Surg. 1982 Aug;144(2):207-10. doi: 10.1016/0002-9610(82)90509-8. Am J Surg. 1982. PMID: 7102927
-
Carotid sonography.Radiology. 1991 Feb;178(2):303-13. doi: 10.1148/radiology.178.2.1987583. Radiology. 1991. PMID: 1987583 Review. No abstract available.
-
Imaging strategies for evaluation of carotid artery disease.J Assoc Physicians India. 1999 May;47(5):519-27. J Assoc Physicians India. 1999. PMID: 10778565 Review. No abstract available.
Cited by
-
A coupled flow-acoustic computational study of bruits from a modeled stenosed artery.Med Biol Eng Comput. 2012 Oct;50(10):1025-35. doi: 10.1007/s11517-012-0917-5. Epub 2012 May 21. Med Biol Eng Comput. 2012. PMID: 22610779
-
Path length entropy analysis of diastolic heart sounds.Comput Biol Med. 2013 Sep;43(9):1154-66. doi: 10.1016/j.compbiomed.2013.05.018. Epub 2013 Jun 6. Comput Biol Med. 2013. PMID: 23930808 Free PMC article. Clinical Trial.
-
Noninvasive assessment of carotid artery disease.West J Med. 1983 Oct;139(4):486-501. West J Med. 1983. PMID: 6649597 Free PMC article.
-
A 3D scaling law for supravalvular aortic stenosis suited for stethoscopic auscultations.Heliyon. 2024 Feb 15;10(4):e26190. doi: 10.1016/j.heliyon.2024.e26190. eCollection 2024 Feb 29. Heliyon. 2024. PMID: 38390109 Free PMC article.
-
Application of the ARMA method to acoustic detection of coronary artery disease.Med Biol Eng Comput. 1991 Jul;29(4):365-72. doi: 10.1007/BF02441656. Med Biol Eng Comput. 1991. PMID: 1787751
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources