Clinical Trial
. 2003 Apr-May;23(3):205-7.
doi: 10.1038/sj.jp.7210886.

Usefulness of the minute ventilation test in predicting successful extubation in newborn infants: a randomized controlled trial

Affiliations
Clinical Trial

Usefulness of the minute ventilation test in predicting successful extubation in newborn infants: a randomized controlled trial

Lorna M Gillespie et al. J Perinatol. 2003 Apr-May.

Abstract

Objective: We performed a prospective, randomized clinical trial to compare the usefulness of the minute ventilation test (MVT) with clinical judgement in predicting readiness for extubation in preterm newborns with respiratory distress syndrome requiring surfactant therapy and mechanical ventilation.

Study design: A total of 42 preterm infants with respiratory distress syndrome were randomized when they reached preselected ventilator settings. The primary outcome measure was the time from study entry to extubation, provided the infant remained extubated for at least 24 hours.

Results: Infants evaluated by the MVT were extubated in a significantly shorter period of time (mean of 8 hours) than those evaluated clinically (mean of 36 hours). The extubation failure rate was similar in the two groups.

Conclusion: The MVT is an easily performed objective measure that can be used to predict readiness for extubation in preterm infants. In this study, it significantly shortened the time for extubation and was not associated with a higher rate of reintubation.

PubMed Disclaimer

Publication types