. 2003 Aug;17(8):1292-7.
doi: 10.1007/s00464-002-8727-8. Epub 2003 May 13.

Combining ultrasonic dissection and the Storz operation rectoscope

Affiliations

Combining ultrasonic dissection and the Storz operation rectoscope

M M Lirici et al. Surg Endosc. 2003 Aug.

Abstract

Background: Transanal endoscopic microsurgery (TEM) allows a precise, full-thickness resection of rectal tumors anywhere within the rectum. Unfortunately, the standard TEM technique needs complex and rather expensive equipment, demands high skill, and is attended by bleeding and oozing that may be challenging. A modified TEM procedure combining the new Storz operation rectoscope and ultrasonic dissection has been developed to overcome the limitations of the original technique.

Methods: The Storz operation rectoscope features a 5-mm telescope combined with a single-monitor display. Standard laparoscopic instruments and the LCSC5 Ultracision Maniple are used for dissection and coagulation. Full-thickness resection is performed most often. Closure of the defect is accomplished by interrupted 3-0 polydoxanone sutures secured by extracorporeal slipknots.

Results: Altogether, 18 TEMs have been performed according to the modified technique: 9 for malignant and 9 for benign lesions. The median operating time was 92.5 min for resection of malignant lesions and 40 min for resection of benign lesions. Two postoperative complications occurred: a bleeding and a partial dehiscence. The median follow-up periods were 35 months for malignant disease and 19.5 months for benign disease. No recurrence was observed.

Conclusion: For tumors located up to 15 cm from the anal verge, TEM with the Storz rectoscope and ultrasonic dissection is indicated. Despite the complication described, coagulation is optimal and ultrasonic scissors allow working in a fairly bloodless field. The overall costs of the equipment are significantly lower.

PubMed Disclaimer

References

    1. Ann Surg. 2001 Sep;234(3):352-8; discussion 358-9 - PubMed
    1. Hepatogastroenterology. 1999 Jul-Aug;46(28):2329-32 - PubMed
    1. Langenbecks Arch Surg. 1998 Oct;383(5):320-4 - PubMed
    1. Scand J Gastroenterol. 1997 Jan;32(1):58-61 - PubMed
    1. Br J Surg. 1997 Mar;84(3):348-51 - PubMed

MeSH terms

LinkOut - more resources