Gastric tonometry: the hemodynamic monitor of choice (Pro)
- PMID: 12740231
- DOI: 10.1378/chest.123.5_suppl.469s
Gastric tonometry: the hemodynamic monitor of choice (Pro)
Abstract
Controversy exists as to the best means to monitor the critically ill patient and the appropriate end points of therapy. Use of global hemodynamic or metabolic parameters may be normal in the patient who has not been completely or adequately resuscitated. Decreased perfusion to the gut is not well tolerated and may contribute to the development of the multiple organ dysfunction syndrome. Gastric tonometry is a minimally invasive way to monitor splanchnic perfusion in the critically ill patient. Data suggest that tonometry is useful for outcome prognostication and for detection of early hypovolemia. In addition, use of gastric intramucosal pH or mucosal-arterial CO(2) gap as end points of resuscitation may be superior to other conventional whole-body parameters. For these reasons, gastric tonometry must be considered the hemodynamic monitor of choice.
Similar articles
-
Gastric mucosal end-tidal PCO2 difference as a continuous indicator of splanchnic perfusion.Br J Anaesth. 2000 Oct;85(4):563-9. doi: 10.1093/bja/85.4.563. Br J Anaesth. 2000. PMID: 11064615
-
Gastric tonometry: the role of mucosal pH measurement in the management of trauma.Chest. 2003 May;123(5 Suppl):475S-81S. doi: 10.1378/chest.123.5_suppl.475s. Chest. 2003. PMID: 12740232 Review.
-
Gastric tonometry and prediction of outcome in the critically ill. Arterial to intramucosal pH gradient and carbon dioxide gradient.Anaesthesia. 1997 Jul;52(7):619-23. doi: 10.1111/j.1365-2044.1997.146-az0150.x. Anaesthesia. 1997. PMID: 9244017
-
Usefulness of continuous air tonometry for evaluation of splanchnic perfusion during cardiopulmonary bypass.ASAIO J. 2003 Jan-Feb;49(1):108-11. doi: 10.1097/00002480-200301000-00017. ASAIO J. 2003. PMID: 12558316 Clinical Trial.
-
Gastric tonometry.Intensive Care Med. 2001 Jan;27(1):317-9. doi: 10.1007/s001340000666. Intensive Care Med. 2001. PMID: 11280658 Review. No abstract available.
Cited by
-
Effects of fluid challenge on gastric mucosal PCO2 in septic patients.Intensive Care Med. 2004 Mar;30(3):423-9. doi: 10.1007/s00134-003-2115-2. Epub 2004 Jan 13. Intensive Care Med. 2004. PMID: 14722633 Clinical Trial.
-
Bladder mucosal CO2 compared with gastric mucosal CO2 as a marker for low perfusion states in septic shock.ScientificWorldJournal. 2012;2012:360378. doi: 10.1100/2012/360378. Epub 2012 Apr 19. ScientificWorldJournal. 2012. PMID: 22593678 Free PMC article.
-
Mucosal tonometry as early warning of gastrojejunal leak in laparoscopic Roux-en-y gastric bypass.Obes Surg. 2012 May;22(5):843-6. doi: 10.1007/s11695-012-0625-0. Obes Surg. 2012. PMID: 22389024
-
Monitoring in the intensive care.Crit Care Res Pract. 2012;2012:473507. doi: 10.1155/2012/473507. Epub 2012 Aug 27. Crit Care Res Pract. 2012. PMID: 22970356 Free PMC article.
-
Methods of monitoring shock.Semin Respir Crit Care Med. 2004 Dec;25(6):629-44. doi: 10.1055/s-2004-860986. Semin Respir Crit Care Med. 2004. PMID: 16088506 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous