Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 May 27;107(20):2551-4.
doi: 10.1161/01.CIR.0000074042.19447.B1. Epub 2003 May 12.

Intramural delivery of recombinant apolipoprotein A-IMilano/phospholipid complex (ETC-216) inhibits in-stent stenosis in porcine coronary arteries

Affiliations

Intramural delivery of recombinant apolipoprotein A-IMilano/phospholipid complex (ETC-216) inhibits in-stent stenosis in porcine coronary arteries

Sanjay Kaul et al. Circulation. .

Abstract

Background: We have previously demonstrated vasculoprotective effects after repeated intravenous administration of recombinant apolipoprotein A-IMilano (apoA-Im)/phospholipid complex. In this study, we sought to determine the effects of local recombinant apoA-Im/1-palmitoyl,2-oleoyl phosphatidylcholine complex (ETC-216) delivered intramurally via the Infiltrator catheter on luminal narrowing in a porcine coronary artery stent overstretch injury model.

Methods and results: In twelve domestic swine ( approximately 25 kg), two arteries each were infiltrated with 0.4 mL ETC-216 (14 mg/mL) or vehicle control immediately before deployment of GFX stents (stent:artery ratio=1.3:1). Animals were euthanized at day 28, and evaluation by QCA revealed a significant improvement in mean lumen loss index with ETC-216 treatment (21+/-22% versus 43+/-13% lumen loss; P=0.01). Histomorphometric analysis showed that ETC-216 treatment significantly reduced the intimal area (6.7+/-1.5 versus 5.2+/-1.4 mm2, -22%; P=0.02) and the stenosis index (0.76+/-0.15 versus 0.59+/-0.15; P=0.01), and increased the lumen area (2.1+/-1.4 versus 3.7+/-1.8 mm2, +76%; P=0.02). Regression analysis showed significant differences in lumen area (P=0.004), neointimal area (P=0.003), stenosis index (P=0.001), and neointimal thickness (P=0.003) adjusted for injury score in favor of ETC-216.

Conclusions: A single intramural administration of ETC-216 significantly inhibited injury-induced luminal narrowing in the porcine stent overstretch model through reduction of intimal hyperplasia. These data show that local intracoronary delivery of ETC-216 may be useful to prevent restenosis after coronary stenting.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources