. 2003 May;25(2):120-6.
doi: 10.1007/s00276-003-0109-y. Epub 2003 May 14.

Measurements of the lumbar pedicles in the Eastern Anatolian population

Affiliations

Measurements of the lumbar pedicles in the Eastern Anatolian population

H H Kadioglu et al. Surg Radiol Anat. 2003 May.

Abstract

Pedicle screw fixation of the spine has become one of the most stable and versatile methods of spine fixation, and knowledge of pedicle morphology is crucial for the safe application of these systems. We undertook this study because only a few reports have investigated Eastern populations. Lumbar pedicle anatomy, i.e., pedicle width (PW) and pedicle height (PH), transverse and sagittal pedicle angles (TPA, SPA), and pedicle length (PL), were assessed in the following two groups: (1) computed tomography scans of 29 normal adults, and (2) 16 dried lumbar spines obtained from the Anatomy Department. Interpedicular distance was different in each group. PW ranged from 4 mm to 14 mm. In both groups, the narrowest PH was 8.2 mm, the widest 19.7 mm. TPA ranged from 6(o) to 19(o) and increased from L1 to L5. In the sagittal plane, the pedicles angled caudally at L5. PL was longest at L1 and shortest at L5. In conclusion, pedicle dimensions and angles may show individual and structural differences. Our data were not significantly different from previous reported data. A detailed knowledge of these relationships is important for any surgery involving screw purchase via a pedicle, to prevent screw cutout and failure of fixation or neurological injury. Selection of the proper diameter of screw is an important issue for safe placement. Knowledge of the pedicle axis length is essential in choosing screw lengths but should always be checked intraoperatively with fluoroscopic control during screw insertion.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Spine (Phila Pa 1976). 1993 Oct 1;18(13):1856-61 - PubMed
    1. Acta Orthop Scand. 1996 Feb;67(1):63-8 - PubMed
    1. Spine (Phila Pa 1976). 1983 Nov-Dec;8(8):817-31 - PubMed
    1. Spine (Phila Pa 1976). 1992 Mar;17(3):299-306 - PubMed
    1. Spine (Phila Pa 1976). 1988 Oct;13(10):1082-6 - PubMed

LinkOut - more resources