Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 Apr;145(4):265-72; discussion 272.
doi: 10.1007/s00701-002-1067-6.

Craniocervical junction instability: instrumentation and fusion with titanium rods and sublaminar wires. Effectiveness and failures in personal experience

Affiliations

Craniocervical junction instability: instrumentation and fusion with titanium rods and sublaminar wires. Effectiveness and failures in personal experience

M Visocchi et al. Acta Neurochir (Wien). 2003 Apr.

Abstract

Background: The aim of the study was to evaluate the effectiveness, pitfalls and failures of instrumentation and fusion with titanium wires and rods in 12 h patients with craniovertebral junction instability.

Methods: Among nine adult patients (mean age 48.11 years) with craniovertebral junction instability, four had basilar impression, three metastatic disease, one rheumatoid arthritis and one Down's syndrome. Three children (mean age 7.33 years) with genetic (Down's syndrome, 2 cases) and metabolic (mucopolisaccarydoses type IV, i.e. Morquio Syndrome, 1 case) disease were studied as well. Each patient underwent preoperative radiological evaluation by means of X-Ray, CT scan and MRI of the craniocervical region. Occipitocervical instrumentation with a titanium U-shaped wired rod was performed in each patient. Autologous bone fusion was performed in all but the two cancer patients, in whom polymethylmetacrylate was used. Postoperatively, all the patients used an external orthosis for 3-6 months. Post-operative X-Ray, CT and MRI were performed on each patient. The Frankel clinical scale was used to asses the outcome at follow-up which ranged from 1 to 10 years. At maximum follow up, there was either clinical improvement or stabilization recorded in all but one patient. This patient with basilar impression transiently worsened from grade D to C and a spinal cord lesion was already evident before the operation on MRI examination.

Interpretation: The effectiveness of surgical management of craniovertebral junction instability by instrumentation and fusion was demonstratedly in our experience. Nevertheless, the choice of the surgical technique should be made with caution when a spinal cord lesion is revealed by preoperative neuroimaging studies.

PubMed Disclaimer

Similar articles

Cited by

Publication types

MeSH terms

LinkOut - more resources