The effect of echo contrast agent on Doppler velocity measurements
- PMID: 12754076
- DOI: 10.1016/s0301-5629(02)00770-6
The effect of echo contrast agent on Doppler velocity measurements
Abstract
The purpose of this investigation was to determine the effect of echo contrast agents on spectral Doppler velocity measurements. SH U 508A was administered by IV injection in 15 patients. The transmitral flow velocity was measured at the E- and A-wave peaks before the start and at the peak of the contrast effect. The Doppler velocity was determined from the Doppler video spectral display and from power spectral analysis of the audio Doppler signal. The Doppler signal intensity was also measured. The Doppler signal intensity increased 17.4 +/- 3.5 dB (p < 0.0001) following echo contrast injection. This was associated with a significant increase in the spectral peak velocity as determined from either the video display or audio analysis. (p < 0.0001). The velocity corresponding to the audio power peak frequency (the modal velocity) did not change significantly (p = NS) and was independent of Doppler signal strength.
Similar articles
-
Improved Doppler signal intensity in coronary arteries after intravenous peripheral injection of a lung-crossing contrast agent (SHU 508A).J Am Coll Cardiol. 1994 Jan;23(1):184-90. doi: 10.1016/0735-1097(94)90518-5. J Am Coll Cardiol. 1994. PMID: 8277078
-
Improved transvalvular continuous-wave Doppler signal intensity after intravenous Albunex injection in patients with prosthetic aortic valves.J Am Soc Echocardiogr. 1997 Jul-Aug;10(6):608-12. doi: 10.1016/s0894-7317(97)70023-3. J Am Soc Echocardiogr. 1997. PMID: 9282350
-
Clinical evaluation of left heart Doppler contrast enhancement by a saccharide-based transpulmonary contrast agent. The Levovist Cardiac Working Group.J Am Coll Cardiol. 1995 Feb;25(2):500-8. doi: 10.1016/0735-1097(94)00404-e. J Am Coll Cardiol. 1995. PMID: 7829806 Clinical Trial.
-
[Determination of transmitral blood flow by pulsed echodoppler. Correlation with aortic blood flow in 30 patients].Arch Mal Coeur Vaiss. 1991 Jul;84(7):957-65. Arch Mal Coeur Vaiss. 1991. PMID: 1929715 Review. French.
-
Evaluation of left ventricular diastolic function.Cardiol Clin. 1990 May;8(2):315-32. Cardiol Clin. 1990. PMID: 2189564 Review.
Cited by
-
Influence of ultrasound contrast agents on spectral Doppler analysis in recipients of liver transplantation.Clin Mol Hepatol. 2017 Sep;23(3):224-229. doi: 10.3350/cmh.2016.0064. Epub 2017 Jul 4. Clin Mol Hepatol. 2017. PMID: 28669174 Free PMC article.
-
Grey scale enhancement of rabbit liver and kidney by intravenous injection of a new lipid-coated ultrasound contrast agent.World J Gastroenterol. 2004 Aug 15;10(16):2369-72. doi: 10.3748/wjg.v10.i16.2369. World J Gastroenterol. 2004. PMID: 15285021 Free PMC article.
-
The Posterior Cerebral Artery and its Main Cortical Branches Identified with Noninvasive Transcranial Color-Coded Duplex Sonography.Ultrasound Int Open. 2015 Nov;1(2):E53-7. doi: 10.1055/s-0035-1565130. Epub 2015 Nov 6. Ultrasound Int Open. 2015. PMID: 27689154 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Miscellaneous