Clinical Trial
. 2003 May-Jun;28(3):267-73.

Microleakage evaluation of a flowable polyacid-modified resin composite used as fissure sealant on air-abraded permanent teeth

Affiliations
  • PMID: 12760698
Clinical Trial

Microleakage evaluation of a flowable polyacid-modified resin composite used as fissure sealant on air-abraded permanent teeth

H Cem Güngör et al. Oper Dent. 2003 May-Jun.

Abstract

This study evaluated the microleakage of a flowable polyacid-modified resin composite used as a fissure sealant on air-abraded teeth in comparison to a resin-based fluoride sealant. Sixty extracted human third molars were divided into six subgroups (n = 10) under two main groups (fissure sealant materials). The occlusal surfaces of the teeth were air-abraded at 80 psi using 50 microm particles of aluminum oxide for 30 seconds, followed by rinsing and drying. Delton FS+ (Dentsply International) and Dyract Flow (Dentsply DeTrey) were applied to the teeth in subgroups following application of: a) an acid etching and bonding agent, b) bonding agent alone or c) air-abrasion alone, respectively. Acid etching (Delton EZ Etch, Dentsply International) and bonding agent application (Prime & Bond NT, Dentsply DeTrey) were done according to the manufacturers' instructions. The teeth were thermocycled for 500 cycles between 5 degrees C and 55 degrees C with dwell time of 15 seconds. Basic fuchsin (0.5%) staining followed by buccolingual sectioning was performed. Microleakage was evaluated at 20x optical magnification. Kruskal-Wallis test was used to make comparisons among six subgroups. Pairwise comparisons were done with the Mann-Whitney U test with the level of significance set as alpha = 0.05. Dyract Flow application as a fissure sealant on air-abraded permanent teeth in combination with acid etching and/or bonding agent provided microleakage results comparable to Delton FS+. Results also showed that the use of air abrasion, alone, resulted in significantly higher microleakage scores.