Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2003 Jun;180(6):1639-47.
doi: 10.2214/ajr.180.6.1801639.

Diagnostic accuracy of phase-inversion tissue harmonic imaging versus fundamental B-mode sonography in the evaluation of focal lesions of the kidney

Affiliations
Comparative Study

Diagnostic accuracy of phase-inversion tissue harmonic imaging versus fundamental B-mode sonography in the evaluation of focal lesions of the kidney

Thorsten Schmidt et al. AJR Am J Roentgenol. 2003 Jun.

Abstract

Objective: We compared phase-inversion tissue harmonic imaging with fundamental B-mode sonography in the evaluation of focal lesions of the kidney.

Subjects and methods: For our prospective study, 114 patients underwent sonography of the kidneys in both modes, fundamental B-mode sonography and phase-inversion tissue harmonic imaging, in a randomly chosen scanning order. Imaging parameters were standardized. Sonographic diagnoses were made under real-time conditions by the examining radiologist. All sonographic diagnoses were compared with a diagnostic reference modality: contrast-enhanced CT, contrast-enhanced MR imaging, or histopathology. Three radiologists different from the examiners evaluated overall image quality, lesion conspicuity, and fluid-solid differentiation for both modalities using hard-copy images.

Results: In 70 patients, fundamental B-mode sonography as the first technique depicted 73 of 111 lesions 10 mm or larger and enabled 71 lesions to be correctly characterized (sensitivity, 65.8%; accuracy, 64.0%). As the first mode, phase-inversion tissue harmonic imaging depicted 57 of 65 focal lesions and enabled 54 lesions to be accurately classified in 44 patients (sensitivity, 87.7%; accuracy, 83.1%). The differences in sensitivity and accuracy were statistically significant (95% confidence interval). For overall image quality, lesion conspicuity, and fluid-solid differentiation phase-inversion harmonic imaging was superior to fundamental B-mode sonography (p < 0.0001).

Conclusion: Phase-inversion tissue harmonic imaging is superior to fundamental B-mode sonography in the sonography of focal kidney lesions because phase-inversion tissue harmonic imaging has better overall image quality, lesion conspicuity, and fluid-solid differentiation. In six cases, phase-inversion tissue harmonic imaging added crucial diagnostic information that changed patient management.