Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 Jun;18(5):389-92.
doi: 10.1016/s0268-0033(03)00041-x.

No effects of cervical spine motion on cranial dura mater strain

Affiliations

No effects of cervical spine motion on cranial dura mater strain

Veronique Feipel et al. Clin Biomech (Bristol). 2003 Jun.

Abstract

Objective: The aim of this study was to analyze the effects of cervical spine motion on cranial dura mater length variations in anatomical specimens using high-resolution linear displacement transducers. We hypothesized that transducer resolution was sufficient to measure dura mater length changes if they occurred during cervical spine motion.

Design: Cranial dura mater strain was measured using differential variable reluctance transducers during cervical spine motion in 11 formaldehyde-fixed whole-body anatomical specimens (mean age: 82 years).

Background: Several theories hypothesize that functional maneuvers carried out on the spine have an effect on intra-cranial structures due to the supposed continuity of spinal and cranial dura mater. The displacements of the spinal dura mater are supposed to be transmitted to the cranial dura mater.

Methods: Eleven anatomical specimens were used. Each specimen (positioned supine) was provided with three openings in the skull (frontal and parietal regions), leaving the dura mater intact. A differential variable reluctance transducer was inserted in frontal or sagittal orientation in the dura mater exposed in each opening. Strain was recorded during cyclic motions of cervical spine flexion-extension, lateral bending and axial rotation.

Results: Average length changes ranged from 0.01 to 0.13% (SD 0.01-0.21%) of initial length for all motions and locations studied, which in all cases was less than the accuracy of the transducers.

Conclusion: It can thus be concluded that cervical spine motion does not induce significant strain of the cerebral dura mater.

Relevance: The present study does not support theories that are based on the transmission of strains from spinal to cranial dura mater.

PubMed Disclaimer

Similar articles

Cited by