Durability of aortouniiliac endografting with femorofemoral crossover: 4-year experience in the Evt/Guidant trials
- PMID: 12764256
- DOI: 10.1016/s0741-5214(03)00327-6
Durability of aortouniiliac endografting with femorofemoral crossover: 4-year experience in the Evt/Guidant trials
Abstract
Objectives: We evaluated mid-term results of the multicenter EVT/Guidant aortouniiliac endograft (AI) trial and ascertained the durability of this endovascular technique in patients unable to undergo standard bifurcated endografting.
Methods: From November 1996 to December 1998, 121 patients were enrolled to receive the AI device on the basis of complex iliac artery anatomy contraindicating bifurcated endografting. Clinical data were centrally collected, and radiographic data were evaluated by core facility.
Results: AI placement was technically successful in 113 of 121 patients. At operation, patients who underwent AI had significantly more arrhythmias, congestive heart failure, and peripheral occlusive disease (P <.05) compared with patients who underwent open aneurysmorrhaphy in the EVT/Guidant trials, indicating comorbid features in this anatomic cohort. Distal AI attachment was performed to the external iliac artery in 40 (36%) patients. Median follow-up was 38 months. In the AI group, overall aneurysm diameter decreased over the duration of study from 54.4 +/- 9.6 mm to 44.4 +/- 16.4 mm (P =.004). At 24 and 36 months after repair, reduction in aneurysm size was associated with absence of endoleak (P =.003 and P =.008, respectively). Aneurysms shrunk or remained stable in 109 (96.5%) patients. Endoleak was identified in 52.3% of patients at discharge, and at follow-up in 30.9% at 1 year, 34.8% at 2 years, 28.6% at 3 years, and 30.4% at 4 years. Type II endoleak predominated. Leak from failure to completely occlude contralateral iliac flow accounted for 8 of 58 endoleaks (13.8%) at discharge. Sixteen patients (14.2%) underwent postoperative endoleak treatment; in one of these patients open conversion was necessary at 20 months. Post-procedure thigh or buttock claudication developed in 16 patients (14.2%). Thirteen patients (81.3%) had either distal attachment in the external iliac artery or contralateral type IIA occlusion. Fifteen patients (13.3%) required intervention because of reduced limb flow; one of these patients underwent open conversion at 27 months, and another underwent axillofemoral grafting at 28 months. Device migration was confirmed in 2 (1.8%) patients, without current clinical sequelae. Whereas no femorofemoral graft thromboses occurred, graft infection developed in 3 patients (2.6%). During follow-up, aneurysm in 2 patients ruptured. Late death occurred in 41 patients (36.3%). Twenty-four patients (58.5%) died of cardiopulmonary disease; one death was endograft-related after aneurysm rupture; and one death was related to femorofemoral bypass infection. Actuarial survival was 78.4% (95% confidence interval [CI], 71%-86%) at 2 years and 63.4% (95% CI, 54%-73%) at 4 years.
Conclusions: In patients with significant comorbid conditions and complex iliac anatomy unfavorable for bifurcated endografting, AI with femorofemoral bypass grafting is safe and effective. In most patients this endovascular option provides satisfactory mid-term results.
Similar articles
-
Durability of femorofemoral bypass grafting after aortouniiliac endovascular aneurysm repair.J Vasc Surg. 2003 Sep;38(3):498-503. doi: 10.1016/s0741-5214(03)00415-4. J Vasc Surg. 2003. PMID: 12947267
-
Utility and reliability of endovascular aortouniiliac with femorofemoral crossover graft for aortoiliac aneurysmal disease.J Vasc Surg. 2000 Jun;31(6):1135-41. doi: 10.1067/mva.2000.107120. J Vasc Surg. 2000. PMID: 10842150
-
External iliac artery-to-internal iliac artery endograft: a novel approach to preserve pelvic inflow in aortoiliac stent grafting.J Vasc Surg. 2002 Jan;35(1):120-4. doi: 10.1067/mva.2002.120038. J Vasc Surg. 2002. PMID: 11802142
-
Endovascular treatment of aortic aneurysms of the abdominal aorta with covered stents.Cardiologia. 1999 Nov;44(11):949-56. Cardiologia. 1999. PMID: 10686769 Review.
-
Simple technique to ensure coaxial guidewire positioning for placement of iliac limb of modular aortic endograft.J Interv Cardiol. 2003 Jun;16(3):223-6. doi: 10.1034/j.1600-0854.2003.8046.x. J Interv Cardiol. 2003. PMID: 12800400 Review.
Cited by
-
Abdominal endovascular aneurysm repair using an aorto-uni-iliac device resulting in resting lower extremity pain: a case report and discussion on patient selection.J Surg Case Rep. 2024 Aug 28;2024(8):rjae557. doi: 10.1093/jscr/rjae557. eCollection 2024 Aug. J Surg Case Rep. 2024. PMID: 39211369 Free PMC article.
-
Technical tips and procedural steps in endovascular aortic aneurysm repair with concomitant recanalization of iliac artery occlusions.Springerplus. 2013 Nov 13;2:605. doi: 10.1186/2193-1801-2-605. eCollection 2013. Springerplus. 2013. PMID: 24294549 Free PMC article.
-
Minimally Invasive Two-Stage Procedure of Aorto-Bi-Iliac Stent-Graft Implantation Performed in a Patient with an Abdominal Aortic Aneurysm and Long-Segment Iliac Artery Occlusion: A Case Report.Am J Case Rep. 2022 Nov 12;23:e937508. doi: 10.12659/AJCR.937508. Am J Case Rep. 2022. PMID: 36369728 Free PMC article.
-
Aorto-Uni-Iliac Stent Grafts with and without Crossover Femorofemoral Bypass for Treatment of Abdominal Aortic Aneurysms: A Parallel Observational Comparative Study.Int J Vasc Med. 2015;2015:962078. doi: 10.1155/2015/962078. Epub 2015 Dec 3. Int J Vasc Med. 2015. PMID: 26770825 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources