[Flat-panel detectors in X-ray systems]
- PMID: 12764582
- DOI: 10.1007/s00117-003-0890-y
[Flat-panel detectors in X-ray systems]
Abstract
For all application segments X-ray systems with flat-panel detectors increasingly enter the market. In digital radiography,mammography and cardiologic angiography flat-panel detectors are already well established while they are made ready for market introduction in general angiography and fluoroscopy. Two flat-panel detector technologies are available. One technology is based on an indirect conversion process of X-rays while the other one uses a direct conversion method. For radiography and dynamic applications the indirect method provides substantial advantages, while the direct method has some benefits for mammography. In radiography and mammography flat-panel detectors lead to clear improvements with respect to workflow, image quality and dose reduction potentials. These improvements are fostered by the immediate availability of the image, the large dynamic range and the high sensitivity to X-rays. New applications and the use of complex image processing algorithms have the potential to enlarge the present diagnostic range of applications. Up to now, image intensifiers are still the well-established technology for angiography and fluoroscopy. Nevertheless flat-panel detectors begin to enter this field, especially in cardiologic angiography. Characteristics of flat-panel detectors such as the availability of distortion-free images, the excellent contrast resolution, the large dynamic range, the high sensitivity to X-rays and the usability in magnetic fields provide the basis for improved and new diagnostic and interventional methods.
Similar articles
-
The design and imaging characteristics of dynamic, solid-state, flat-panel x-ray image detectors for digital fluoroscopy and fluorography.Clin Radiol. 2008 Oct;63(10):1073-85. doi: 10.1016/j.crad.2008.06.002. Clin Radiol. 2008. PMID: 18774353 Review.
-
Flat detectors and their clinical applications.Eur Radiol. 2005 Sep;15(9):1934-47. doi: 10.1007/s00330-005-2734-9. Epub 2005 Apr 2. Eur Radiol. 2005. PMID: 15806363
-
Technical advances of interventional fluoroscopy and flat panel image receptor.Health Phys. 2008 Nov;95(5):650-7. doi: 10.1097/01.HP.0000326336.40775.94. Health Phys. 2008. PMID: 18849699
-
Solid-state, flat-panel, digital radiography detectors and their physical imaging characteristics.Clin Radiol. 2008 May;63(5):487-98. doi: 10.1016/j.crad.2007.10.014. Epub 2008 Jan 31. Clin Radiol. 2008. PMID: 18374710 Review.
-
The evolution of digital radiography: from storage phosphors to flat-panel detectors.Rays. 2003 Jan-Mar;28(1):5-12. Rays. 2003. PMID: 14509175
Cited by
-
[Feasibility of flat-panel volumetric computed tomography (fpVCT) in experimental small animal imaging of osteoporosis - initial experience].Radiologe. 2006 Oct;46(10):893-9. doi: 10.1007/s00117-006-1390-7. Radiologe. 2006. PMID: 16775690 German.
-
[Flat panel technology in the orthopaedic trauma operating room].Unfallchirurg. 2012 Mar;115(3):202-8. doi: 10.1007/s00113-011-2120-9. Unfallchirurg. 2012. PMID: 22406916 German.
-
Modification of chest radiography exposure parameters using a neonatal chest phantom.Pediatr Radiol. 2020 Jan;50(1):28-37. doi: 10.1007/s00247-019-04522-1. Epub 2019 Oct 4. Pediatr Radiol. 2020. PMID: 31583441
-
Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience.Eur Radiol. 2005 Feb;15(2):329-33. doi: 10.1007/s00330-004-2537-4. Epub 2004 Nov 20. Eur Radiol. 2005. PMID: 15662479
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources