[New computed radiography technologies in digital radiography]
- PMID: 12764585
- DOI: 10.1007/s00117-003-0891-x
[New computed radiography technologies in digital radiography]
Abstract
Digital radiography (DR) has become integral to modern diagnostic radiology. One of the earliest forms of DR, computed radiography (CR) using storage phosphors, has established itself as the mainstay of DR-based diagnostic imaging over the past 20 years. More recently, flat-panel DR systems based on solid state X-ray detectors with integrated, large-area, active-matrix readout electronics are promising further improvements in clinical workflow and image quality. Despite CR's longevity, innovations continue to be made. New developments in CR screen technologies, like structured (needle) screens, and new scanner concepts based on line-at-a-time reading promise major improvements in image quality (comparable to that of flat-panel systems), system through-put and physical size, at a cost comparable to that of today's systems. Thus, despite the advent of flat-panel acquisition systems, there will still be an important role for CR in the foreseeable future. After a brief review of the current state of CR technology, this paper will explore several of these new CR developments and present some examples of their potential clinical impact.
Similar articles
-
Solid-state, flat-panel, digital radiography detectors and their physical imaging characteristics.Clin Radiol. 2008 May;63(5):487-98. doi: 10.1016/j.crad.2007.10.014. Epub 2008 Jan 31. Clin Radiol. 2008. PMID: 18374710 Review.
-
Advances in computed radiography systems and their physical imaging characteristics.Clin Radiol. 2007 Dec;62(12):1132-41. doi: 10.1016/j.crad.2007.07.009. Epub 2007 Sep 7. Clin Radiol. 2007. PMID: 17981160 Review.
-
Status and prospects of digital detector technology for CR and DR.Radiat Prot Dosimetry. 2005;114(1-3):32-8. doi: 10.1093/rpd/nch532. Radiat Prot Dosimetry. 2005. PMID: 15933078 Review.
-
[Flat-panel detectors in X-ray systems].Radiologe. 2003 May;43(5):340-50. doi: 10.1007/s00117-003-0890-y. Radiologe. 2003. PMID: 12764582 German.
-
[The amorphous selenium based flat-panel detector. Clinical experiences].Radiologe. 2003 May;43(5):374-8. doi: 10.1007/s00117-003-0892-9. Radiologe. 2003. PMID: 12764586 German.
Cited by
-
[The future of bedside chest radiography: Comparative study of mobile flat-panels and needle-image plate storage phosphor systems].Med Klin Intensivmed Notfmed. 2015 Nov;110(8):603-8. doi: 10.1007/s00063-015-0022-2. Epub 2015 Apr 24. Med Klin Intensivmed Notfmed. 2015. PMID: 25905891 German.
-
[Digital radiography of the chest in pediatric patients].Radiologe. 2003 Dec;43(12):1045-50. doi: 10.1007/s00117-003-0983-7. Radiologe. 2003. PMID: 14668992 Review. German.
-
[Dose reduction and adequate image quality in digital radiography: a contradiction?].Radiologe. 2012 Oct;52(10):898-904. doi: 10.1007/s00117-012-2337-9. Radiologe. 2012. PMID: 22986575 German.
-
Needle-based storage-phosphor detector radiography is superior to a conventional powder-based storage phosphor detector and a high-resolution screen-film system in small patients (budgerigars and mice).Sci Rep. 2019 Jul 11;9(1):10057. doi: 10.1038/s41598-019-46546-5. Sci Rep. 2019. PMID: 31296929 Free PMC article.
-
[Balance of required dose and image quality in digital radiography].Radiologe. 2008 Mar;48(3):249-57. doi: 10.1007/s00117-008-1617-x. Radiologe. 2008. PMID: 18259724 Review. German.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous