[The use of flat-panel detectors for CT imaging]
- PMID: 12764587
- DOI: 10.1007/s00117-003-0897-4
[The use of flat-panel detectors for CT imaging]
Abstract
Clinical CT has reached a very high performance level by now. The introduction of spiral scanning and of multirow detectors have allowed to image even large body sections in very short time and with isotropic, high spatial resolution of better than 1 mm. For further improvements with respect to detector technology the use of flat-panel detectors (FPD), which have been developed for radiographic applications, is currently under investigation. In this article we discuss the general demands on CT detectors and specifically the suitability of FPDs with respect to CT imaging. FPDs offer excellent performance for the imaging of high-contrast structures with high spatial resolution.Low-contrast resolution and dose efficiency, however, do not yet reach the level of performance of dedicated CT detectors; temporal resolution is also limited. FPDs appear primarily suited for special applications in CT as for example 3D angiography or intraoperative imaging which also allows for improvements in workflow. For standard diagnostic CT they are not to be recommended at present, last but not least for dose reasons. The respective technical developments will have to be reassessed constantly in the future. The development of detector systems which are equally suited for radiography and CT constitutes an attractive goal.
Similar articles
-
[Flat-panel detectors in X-ray systems].Radiologe. 2003 May;43(5):340-50. doi: 10.1007/s00117-003-0890-y. Radiologe. 2003. PMID: 12764582 German.
-
Solid-state, flat-panel, digital radiography detectors and their physical imaging characteristics.Clin Radiol. 2008 May;63(5):487-98. doi: 10.1016/j.crad.2007.10.014. Epub 2008 Jan 31. Clin Radiol. 2008. PMID: 18374710 Review.
-
X-ray computed tomography.Phys Med Biol. 2006 Jul 7;51(13):R29-43. doi: 10.1088/0031-9155/51/13/R03. Epub 2006 Jun 20. Phys Med Biol. 2006. PMID: 16790909 Review.
-
[New computed radiography technologies in digital radiography].Radiologe. 2003 May;43(5):367-73. doi: 10.1007/s00117-003-0891-x. Radiologe. 2003. PMID: 12764585 German.
-
[Digital thorax radiography: flat-panel detector or storage phosphor plates].Radiologe. 2003 May;43(5):351-61. doi: 10.1007/s00117-003-0893-8. Radiologe. 2003. PMID: 12764583 German.
Cited by
-
Minimally Invasive Cochlear Implantation Assisted by Bi-planar Device: An Exploratory Feasibility Study in vitro.Chin Med J (Engl). 2016 Oct 20;129(20):2476-2483. doi: 10.4103/0366-6999.191787. Chin Med J (Engl). 2016. PMID: 27748341 Free PMC article.
-
Traumatic injuries of the pelvis and thoracic and lumbar spine: does thin-slice multidetector-row CT increase diagnostic accuracy?Eur Radiol. 2004 Oct;14(10):1751-60. doi: 10.1007/s00330-004-2424-z. Epub 2004 Aug 5. Eur Radiol. 2004. PMID: 15300395
-
C-arm CT measurement of cerebral blood volume and cerebral blood flow using a novel high-speed acquisition and a single intravenous contrast injection.AJNR Am J Neuroradiol. 2013 Nov-Dec;34(11):2131-8. doi: 10.3174/ajnr.A3536. Epub 2013 May 23. AJNR Am J Neuroradiol. 2013. PMID: 23703149 Free PMC article.
-
[Flat-detector computed tomography in diagnostic and interventional neuroradiology].Radiologe. 2009 Sep;49(9):820-9. doi: 10.1007/s00117-009-1861-8. Radiologe. 2009. PMID: 19727642 Review. German.
-
Analysis of tumor vessel supply in Lewis lung carcinoma in mice by fluorescent microsphere distribution and imaging with micro- and flat-panel computed tomography.Am J Pathol. 2005 Oct;167(4):937-46. doi: 10.1016/S0002-9440(10)61184-4. Am J Pathol. 2005. PMID: 16192630 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical