A dosimetry study comparing NCS report-5, IAEA TRS-381, AAPM TG-51 and IAEA TRS-398 in three clinical electron beam energies
- PMID: 12765324
- DOI: 10.1088/0031-9155/48/9/301
A dosimetry study comparing NCS report-5, IAEA TRS-381, AAPM TG-51 and IAEA TRS-398 in three clinical electron beam energies
Abstract
New codes of practice for reference dosimetry in clinical high-energy photon and electron beams have been published recently, to replace the air kerma based codes of practice that have determined the dosimetry of these beams for the past twenty years. In the present work, we compared dosimetry based on the two most widespread absorbed dose based recommendations (AAPM TG-51 and IAEA TRS-398) with two air kerma based recommendations (NCS report-5 and IAEA TRS-381). Measurements were performed in three clinical electron beam energies using two NE2571-type cylindrical chambers, two Markus-type plane-parallel chambers and two NACP-02-type plane-parallel chambers. Dosimetry based on direct calibrations of all chambers in 60Co was investigated, as well as dosimetry based on cross-calibrations of plane-parallel chambers against a cylindrical chamber in a high-energy electron beam. Furthermore, 60Co perturbation factors for plane-parallel chambers were derived. It is shown that the use of 60Co calibration factors could result in deviations of more than 2% for plane-parallel chambers between the old and new codes of practice, whereas the use of cross-calibration factors, which is the first recommendation in the new codes, reduces the differences to less than 0.8% for all situations investigated here. The results thus show that neither the chamber-to-chamber variations, nor the obtained absolute dose values are significantly altered by changing from air kerma based dosimetry to absorbed dose based dosimetry when using calibration factors obtained from the Laboratory for Standard Dosimetry, Ghent, Belgium. The values of the 60Co perturbation factor for plane-parallel chambers (k(att) x k(m) for the air kerma based and p(wall) for the absorbed based codes of practice) that are obtained from comparing the results based on 60Co calibrations and cross-calibrations are within the experimental uncertainties in agreement with the results from other investigators.
Similar articles
-
Comparison of the IAEA TRS-398 and AAPM TG-51 absorbed dose to water protocols in the dosimetry of high-energy photon and electron beams.Phys Med Biol. 2001 Nov;46(11):2985-3006. doi: 10.1088/0031-9155/46/11/315. Phys Med Biol. 2001. PMID: 11720359
-
Protocols for the dosimetry of high-energy photon and electron beams: a comparison of the IAEA TRS-398 and previous international codes of practice. International Atomic Energy Agency.Phys Med Biol. 2002 Sep 7;47(17):3033-53. doi: 10.1088/0031-9155/47/17/301. Phys Med Biol. 2002. PMID: 12361209
-
Absorbed dose to water based dosimetry versus air kerma based dosimetry for high-energy photon beams: an experimental study.Phys Med Biol. 2002 Feb 7;47(3):421-40. doi: 10.1088/0031-9155/47/3/305. Phys Med Biol. 2002. PMID: 11848121
-
Dosimetry of small static fields used in external photon beam radiotherapy: Summary of TRS-483, the IAEA-AAPM international Code of Practice for reference and relative dose determination.Med Phys. 2018 Nov;45(11):e1123-e1145. doi: 10.1002/mp.13208. Epub 2018 Oct 17. Med Phys. 2018. PMID: 30247757 Review.
-
Advances in the determination of absorbed dose to water in clinical high-energy photon and electron beams using ionization chambers.Phys Med Biol. 2004 Feb 21;49(4):R49-104. doi: 10.1088/0031-9155/49/4/r01. Phys Med Biol. 2004. PMID: 15005158 Review.
Cited by
-
Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia.Med Sci Monit. 2011 Jul;17(7):MT51-5. doi: 10.12659/msm.881833. Med Sci Monit. 2011. PMID: 21709641 Free PMC article.
-
Evaluation of clinical use of OneDose metal oxide semiconductor field-effect transistor detectors compared to thermoluminescent dosimeters to measure skin dose for adult patients with acute lymphoblastic leukemia.N Am J Med Sci. 2011 Aug;3(8):362-6. doi: 10.4297/najms.2011.3362. N Am J Med Sci. 2011. PMID: 22171243 Free PMC article.