Characterizing the motion of total knee replacements in laboratory tests
Abstract
The purposes of determining the motion of a total knee replacement in vitro are to characterize the stability and laxity characteristics and to predict the kinematic behavior of the total knee replacement when implanted. With this information, different total knee replacement designs can be compared, the stability of the implanted knee replacement with and without the retention of ligaments can be assessed, and tests can be formulated to measure the wear and deformation of the materials, the strength of the components, and the fixation to the bone. Initially, different ways are described for characterizing the kinematics of the natural knee. We propose a rationale for the kinematic testing of total knee replacements in vitro using mechanical tests. One of the key questions is whether there is an objective method of measuring the kinematics of a total knee replacement in vitro, which will relate to or predict its behavior in vivo.
Similar articles
-
The influence of design, materials and kinematics on the in vitro wear of total knee replacements.J Biomech. 2005 Feb;38(2):357-65. doi: 10.1016/j.jbiomech.2004.02.015. J Biomech. 2005. PMID: 15598464
-
Effect of joint laxity on polyethylene wear in total knee replacement.J Biomech. 2010 Apr 19;43(6):1092-6. doi: 10.1016/j.jbiomech.2009.12.016. Epub 2010 Jan 13. J Biomech. 2010. PMID: 20074735
-
Biomechanics and gait analysis in total knee replacement.Orthop Rev. 1988 May;17(5):470-3. Orthop Rev. 1988. PMID: 3174215
-
Physiologic kinematics as a concept for better flexion in TKA.Clin Orthop Relat Res. 2006 Nov;452:53-8. doi: 10.1097/01.blo.0000238792.36725.1e. Clin Orthop Relat Res. 2006. PMID: 16924173 Review.
-
Optimizing flexion after total knee arthroplasty: advances in prosthetic design.Clin Orthop Relat Res. 2003 Nov;(416):167-73. doi: 10.1097/01.blo.0000081937.75404.ee. Clin Orthop Relat Res. 2003. PMID: 14646757 Review.
Cited by
-
Rotating platform versus fixed-bearing total knees: an in vitro study of wear.Clin Orthop Relat Res. 2008 Nov;466(11):2677-85. doi: 10.1007/s11999-008-0463-5. Epub 2008 Aug 29. Clin Orthop Relat Res. 2008. PMID: 18758877 Free PMC article.
-
Experimental testing of total knee replacements with UHMW-PE inserts: impact of severe wear test conditions.J Mater Sci Mater Med. 2015 Mar;26(3):134. doi: 10.1007/s10856-015-5470-y. Epub 2015 Feb 26. J Mater Sci Mater Med. 2015. PMID: 25716024
-
Femoral and tibial insert downsizing increases the laxity envelope in TKA.Knee Surg Sports Traumatol Arthrosc. 2014 Dec;22(12):3003-11. doi: 10.1007/s00167-014-3339-0. Epub 2014 Oct 2. Knee Surg Sports Traumatol Arthrosc. 2014. PMID: 25274088 Free PMC article.
-
Differences in tibiofemoral kinematics between the unloaded robotic passive path and a weightbearing knee simulator.Orthop Rev (Pavia). 2012 Jan 2;4(1):e2. doi: 10.4081/or.2012.e2. Epub 2012 Jan 3. Orthop Rev (Pavia). 2012. PMID: 22577503 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources