Silica-based monoliths for rapid peptide screening by capillary liquid chromatography hyphenated with electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
- PMID: 12772274
- DOI: 10.1002/rcm.1039
Silica-based monoliths for rapid peptide screening by capillary liquid chromatography hyphenated with electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry
Abstract
Capillary liquid chromatography based on particulate and monolithic stationary phases was used to screen complex peptide libraries by fast gradient elution coupled on-line to electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS). A slightly modified commercial electrospray interface consisting of a fused-silica transfer capillary and low dead volume stainless steel union at which the electrospray voltage was grounded enabled the effluent of all the capillary columns to be directly sprayed into the mass spectrometer. Stable electrospray conditions were generated over a wide range of mobile phase compositions, alleviating the need for a tapered end of the spray capillary, pneumatic assistance or preheated nebulizer gas. Since the identification of complex samples containing numerous isobaric substances is facilitated by chromatographic separation prior to mass spectrometry, stationary phase materials have been employed which offer a fast, efficient elution and, due to the complexity of samples, a high loading capacity. Silica-based monolithic capillary columns combine these three characteristics in a unique manner due to a tailored adjustment of both macro- and mesopore sizes in the highly porous silica structure. As we demonstrate by a comparative study of the silica-based monolithic and packed capillaries for LC/MS analysis of complex peptide libraries, silica monoliths show superior performance over packed beds of small-diameter particles with respect to analysis time and separation efficiency. Libraries with more than 1000 different peptides could be screened in less than 20 min.
Copyright 2003 John Wiley & Sons, Ltd.
Similar articles
-
High-efficiency peptide analysis on monolithic multimode capillary columns: Pressure-assisted capillary electrochromatography/capillary electrophoresis coupled to UV and electrospray ionization-mass spectrometry.Electrophoresis. 2003 Nov;24(21):3663-73. doi: 10.1002/elps.200305620. Electrophoresis. 2003. PMID: 14613191
-
Highly efficient monolithic silica capillary columns modified with poly(acrylic acid) for hydrophilic interaction chromatography.J Chromatogr A. 2007 Sep 14;1164(1-2):198-205. doi: 10.1016/j.chroma.2007.07.012. Epub 2007 Jul 13. J Chromatogr A. 2007. PMID: 17689542
-
More sensitive and quantitative proteomic measurements using very low flow rate porous silica monolithic LC columns with electrospray ionization-mass spectrometry.J Proteome Res. 2006 May;5(5):1091-7. doi: 10.1021/pr050424y. J Proteome Res. 2006. PMID: 16674098
-
Recent development of monolithic stationary phases with emphasis on microscale chromatographic separation.J Chromatogr A. 2008 Mar 14;1184(1-2):369-92. doi: 10.1016/j.chroma.2007.09.022. Epub 2007 Sep 15. J Chromatogr A. 2008. PMID: 17923135 Review.
-
Separation efficiencies in hydrophilic interaction chromatography.J Chromatogr A. 2008 Mar 14;1184(1-2):474-503. doi: 10.1016/j.chroma.2008.01.075. Epub 2008 Feb 3. J Chromatogr A. 2008. PMID: 18294645 Review.
Cited by
-
Improvement of the liquid-chromatographic analysis of protein tryptic digests by the use of long-capillary monolithic columns with UV and MS detection.Anal Bioanal Chem. 2007 May;388(1):195-200. doi: 10.1007/s00216-007-1215-1. Epub 2007 Mar 13. Anal Bioanal Chem. 2007. PMID: 17393153 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Research Materials