Clinical signs of hypoxia with high-Dk soft lens extended wear: is the cornea convinced?
- PMID: 12772725
- DOI: 10.1097/00140068-200301001-00007
Clinical signs of hypoxia with high-Dk soft lens extended wear: is the cornea convinced?
Abstract
Purpose: To assess the effectiveness of high-Dk soft contact lenses with oxygen transmissibility (Dk/L) beyond the critical level required to avoid corneal edema during overnight wear.
Methods: The most up-to-date data available on clinical signs of hypoxia with high-Dk contact lenses is reviewed.
Results: Chronic corneal edema associated with hypoxia is responsible for the development of large numbers of microcysts, limbal hyperemia, neovascularization, and small increases in myopia. Silicone hydrogel lenses worn continuously for up to 30 nights prevent corneal edema during overnight wear and do not induce a microcyst response. Long-term clinical trials indicate the mean level of limbal redness for patients wearing high-Dk lenses during continuous wear are equivalent to nonlens wearers. No changes in refractive error are associated with continuous wear of high-Dk lenses.
Conclusion: High-Dk silicone hydrogel lenses can be worn for up to 3 years with virtual elimination of the hypoxic consequences observed with low-Dk lenses made from conventional lens materials.
Similar articles
-
Vascular response to extended wear of hydrogel lenses with high and low oxygen permeability.Optom Vis Sci. 2001 Mar;78(3):147-51. doi: 10.1097/00006324-200103000-00006. Optom Vis Sci. 2001. PMID: 11327675 Clinical Trial.
-
Changes in myopic refractive error with nine months' extended wear of hydrogel lenses with high and low oxygen permeability.Optom Vis Sci. 1999 Dec;76(12):845-9. doi: 10.1097/00006324-199912000-00020. Optom Vis Sci. 1999. PMID: 10612406 Clinical Trial.
-
Changes in myopia with low-Dk hydrogel and high-Dk silicone hydrogel extended wear.Optom Vis Sci. 2004 Aug;81(8):591-6. doi: 10.1097/01.opx.0000141794.18469.be. Optom Vis Sci. 2004. PMID: 15300117 Clinical Trial.
-
A review of the Holden-Mertz criteria for critical oxygen transmission.Eye Contact Lens. 2005 Nov;31(6):247-51. doi: 10.1097/01.icl.0000182488.70745.1d. Eye Contact Lens. 2005. PMID: 16284501 Review.
-
Have silicone hydrogel lenses eliminated hypoxia?Eye Contact Lens. 2013 Jan;39(1):53-60. doi: 10.1097/ICL.0b013e31827c7899. Eye Contact Lens. 2013. PMID: 23271474 Review.
Cited by
-
A refined model on flow and oxygen consumption in the human cornea depending on the oxygen tension at the interface cornea/post lens tear film during contact lens wear.J Optom. 2022 Apr-Jun;15(2):160-174. doi: 10.1016/j.optom.2020.12.002. Epub 2021 Feb 13. J Optom. 2022. PMID: 33589396 Free PMC article.
-
Dendritic immune cell densities in the central cornea associated with soft contact lens types and lens care solution types: a pilot study.Clin Ophthalmol. 2012;6:511-9. doi: 10.2147/OPTH.S28083. Epub 2012 Mar 28. Clin Ophthalmol. 2012. PMID: 22536045 Free PMC article.
-
The short-term physiological impact of switching reusable silicone hydrogel wearers into a hydrogel daily disposable multifocal.Clin Ophthalmol. 2019 Jul 10;13:1193-1202. doi: 10.2147/OPTH.S208905. eCollection 2019. Clin Ophthalmol. 2019. PMID: 31371916 Free PMC article.
-
Oxygen-deficient metabolism and corneal edema.Prog Retin Eye Res. 2011 Nov;30(6):471-92. doi: 10.1016/j.preteyeres.2011.07.001. Epub 2011 Jul 26. Prog Retin Eye Res. 2011. PMID: 21820076 Free PMC article.
-
Effect of hypoxic stress-activated Polo-like kinase 3 on corneal epithelial wound healing.Invest Ophthalmol Vis Sci. 2010 Oct;51(10):5034-40. doi: 10.1167/iovs.10-5501. Epub 2010 May 26. Invest Ophthalmol Vis Sci. 2010. PMID: 20505196 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources