MR imaging of epilepsy: state of the art at 1.5 T and potential of 3 T
Abstract
Shortly after being introduced in the nineteen eighties, magnetic resonance imaging (MRI) became a key tool for the investigation of patients with epilepsy, due to its ability to acquire high quality images. The strength of the magnetic field of a scanner is measured in tesla (T). This review addresses the clinical and research potential in epilepsy of MR imaging at 1.5 T and 3 T. A typical clinical scanning protocol at 1.5 T for a patient with refractory epilepsy may include T1- and T2-weighted imaging, fluid-attenuated inversion recovery (FLAIR) imaging, and a 3D volume acquisition sequence. A research protocol may add quantification of structural imaging, such as volumetric assessment and T2-relaxometry, together with functional measures, such as MR-spectroscopy, functional MRI and diffusion weighted sequences. MR-spectroscopy assesses the metabolites of the seizure focus and other brain areas. Functional MRI allows localisation of cognitive and sensori-motor function and the ability to assess the spatial relationship of these functions to the seizure focus. Whereas these techniques can be performed at 1.5 T, particularly MR-spectroscopy and functional MRI benefit from increased magnetic field-strength. Higher magnetic field-strength is associated with a higher signal-to-noise ratio (SNR). The increased SNR can allow shorter imaging times for a given resolution, higher resolution for a given imaging time, or combination of both. The use of higher magnetic field-strengths is therefore indicated for the (fast) imaging of ill subjects, for long protocols, including structural, metabolic and functional imaging, and for novel applications, such as continuous EEG recording and functional MRI for the detection of the seizure focus. Disadvantages of MR imaging in epilepsy at a high field-strength of 3 T and above are, apart from engineering and technical challenges, the greater energy deposition into tissue and increased susceptibility to artefacts. So far, magnets of 3 T and above have been used mainly for research applications, however the benefits of high field-strength for MR spectroscopy and functional MRI, and the usefulness of these techniques for the investigation of epilepsy patients are obvious incentives for the use of 3 T systems in routine clinical investigations.
Similar articles
-
3.0-T functional brain imaging: a 5-year experience.Radiol Med. 2007 Feb;112(1):97-112. doi: 10.1007/s11547-007-0124-x. Epub 2007 Feb 22. Radiol Med. 2007. PMID: 17310287 English, Italian.
-
[New techniques of structural and functional MRI].Neurochirurgie. 2008 May;54(3):197-207. doi: 10.1016/j.neuchi.2008.02.037. Epub 2008 Apr 28. Neurochirurgie. 2008. PMID: 18440565 Review. French.
-
Clinical MRI in children and adults with focal epilepsy: a critical review.Epilepsy Behav. 2009 May;15(1):40-9. doi: 10.1016/j.yebeh.2009.02.032. Epub 2009 Feb 21. Epilepsy Behav. 2009. PMID: 19236945 Review.
-
Improved preoperative evaluation of cerebral cavernomas by high-field, high-resolution susceptibility-weighted magnetic resonance imaging at 3 Tesla: comparison with standard (1.5 T) magnetic resonance imaging and correlation with histopathological findings--preliminary results.Invest Radiol. 2007 Jun;42(6):346-51. doi: 10.1097/01.rli.0000262744.85397.fc. Invest Radiol. 2007. PMID: 17507804
-
[Clinical applications of 3.0 T magnetic resonance system in the neuroradiological field].Brain Nerve. 2007 May;59(5):479-85. Brain Nerve. 2007. PMID: 17533973 Review. Japanese.
Cited by
-
3.0-T high-field magnetic resonance imaging of the female pelvis: preliminary experiences.Eur Radiol. 2005 Apr;15(4):639-44. doi: 10.1007/s00330-004-2589-5. Epub 2004 Dec 31. Eur Radiol. 2005. PMID: 15627183
-
Optimizing the magnetization-prepared rapid gradient-echo (MP-RAGE) sequence.PLoS One. 2014 May 30;9(5):e96899. doi: 10.1371/journal.pone.0096899. eCollection 2014. PLoS One. 2014. PMID: 24879508 Free PMC article.
-
MR imaging of the brachial plexus: comparison between 1.5-T and 3-T MR imaging: preliminary experience.Skeletal Radiol. 2011 Jun;40(6):717-24. doi: 10.1007/s00256-010-1050-x. Epub 2010 Oct 23. Skeletal Radiol. 2011. PMID: 20972564
-
Reliability of a new adjustable shunt device without the need for readjustment following 3-Tesla MRI.Childs Nerv Syst. 2005 Mar;21(3):227-9. doi: 10.1007/s00381-004-1084-2. Epub 2005 Jan 19. Childs Nerv Syst. 2005. PMID: 15657786
-
Major depression in temporal lobe epilepsy with hippocampal sclerosis: clinical and imaging correlates.J Neurol Neurosurg Psychiatry. 2007 Nov;78(11):1226-30. doi: 10.1136/jnnp.2006.104521. Epub 2007 Jan 26. J Neurol Neurosurg Psychiatry. 2007. PMID: 17259350 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical