Clinical and electrophysiologic predictors of ventricular tachyarrhythmia recurrence in patients with implantable cardioverter defibrillators
- PMID: 12776866
- DOI: 10.1046/j.1540-8167.2003.02328.x
Clinical and electrophysiologic predictors of ventricular tachyarrhythmia recurrence in patients with implantable cardioverter defibrillators
Abstract
Introduction: Not all patients experience recurrent sustained ventricular tachyarrhythmias after placement of an implantable cardioverter defibrillator (ICD). We evaluated the clinical and electrophysiologic predictors of ventricular tachycardia (VT) and ventricular fibrillation (VF) recurrence following ICD implantation.
Methods and results: Consecutive patients (n = 133) underwent 4 +/- 3 serial electrophysiologic studies (EPS) over 50 +/- 26 months following ICD implantation. Sustained VT/VF could always be induced during follow-up EPS in 49 patients; sustained VT/VF was sometimes induced during follow-up EPS in 47 patients; and sustained VT/VF could never be induced during follow-up EPS in 37 patients. Spontaneous VT/VF requiring ICD therapy occurred in 107 patients during follow-up. Patients with sustained VT/VF that was always inducible or sometimes inducible during follow-up experienced more frequent episodes of VT/VF following ICD implant (20.5, 95% CI 12.7-33.0; and 17.8, 95% CI 11.3-28.1 episodes/patient respectively; vs 3.0, 95% CI 2.0-4.6 episodes/patient for patients with VT/VF never induced, P < 0.001). Inducibility of sustained VT/VF post-ICD implant (P < 0.001) and sustained VT as the presenting arrhythmia (P = 0.02) were independent predictors of spontaneous VT/VF recurrence.
Conclusion: Reproducibly inducible VT/VF following ICD implantation predicts a high probability of VT/VF recurrence and identifies a cohort of patients who experience frequent episodes of VT/VF over time. Persistent noninducibility of sustained VT/VF identifies a group of patients who experience no or very few episodes of VT/VF recurrence.
Similar articles
-
Predictive value of ventricular arrhythmia inducibility for subsequent ventricular tachycardia or ventricular fibrillation in Multicenter Automatic Defibrillator Implantation Trial (MADIT) II patients.J Am Coll Cardiol. 2006 Jan 3;47(1):98-107. doi: 10.1016/j.jacc.2005.08.049. Epub 2005 Dec 15. J Am Coll Cardiol. 2006. PMID: 16386671 Clinical Trial.
-
Gender differences in ventricular arrhythmia recurrence in patients with coronary artery disease and implantable cardioverter-defibrillators.J Am Coll Cardiol. 2004 Jun 16;43(12):2293-9. doi: 10.1016/j.jacc.2004.03.031. J Am Coll Cardiol. 2004. PMID: 15193696
-
Long-term reproducibility of ventricular tachycardia induction in patients with implantable cardioverter/defibrillators. Serial noninvasive studies.Circulation. 1995 May 15;91(10):2605-13. doi: 10.1161/01.cir.91.10.2605. Circulation. 1995. PMID: 7743623
-
The role of the transvenous catheter electrophysiologic study in the evaluation and management of ventricular tachyarrhythmias associated with ischemic heart disease.Card Electrophysiol Rev. 2002 Dec;6(4):458-62. doi: 10.1023/a:1021152812529. Card Electrophysiol Rev. 2002. PMID: 12438828 Review.
-
Is a baseline electrophysiologic study mandatory for the management of patients with spontaneous, sustained, ventricular tachyarrhythmias?Prog Cardiovasc Dis. 1996 Mar-Apr;38(5):385-92. doi: 10.1016/s0033-0620(96)80032-6. Prog Cardiovasc Dis. 1996. PMID: 8604443 Review.
Cited by
-
Sudden cardiac death: time to make a difference: Pro ICD.Neth Heart J. 2006 Dec;14(12):417-419. Neth Heart J. 2006. PMID: 25696582 Free PMC article. No abstract available.
-
The prediction of ICD therapy in multicenter automatic defibrillator implantation trial (MADIT) II like patients: a retrospective analysis.Indian Pacing Electrophysiol J. 2008 Apr 1;8(2):80-93. Indian Pacing Electrophysiol J. 2008. PMID: 18379653 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical