Technical considerations for transabdominal loading of the circular stapler in laparoscopic Roux-en-Y gastric bypass
- PMID: 12781891
- DOI: 10.1016/s0002-9610(03)00063-1
Technical considerations for transabdominal loading of the circular stapler in laparoscopic Roux-en-Y gastric bypass
Abstract
Background: Laparoscopic Roux-en-Y gastric bypass is being undertaken with increasing frequency. We describe a technique for introducing the anvil of the circular stapler using a totally transabdominal approach.
Methods: One hundred consecutive patients underwent laparoscopic Roux-en-Y gastric bypass in a university-affiliated teaching hospital.
Results: The cardiojejunostomy was constructed in all 100 patients using the circular stapler with no complications. No anastomotic leaks were detected postoperatively.
Conclusions: The totally transabdominal approach for introducing the anvil of the circular stapler into the gastric pouch is safe and feasible.