A randomized controlled trial of blood flow and stenosis surveillance of hemodialysis grafts
- PMID: 12787419
- DOI: 10.1046/j.1523-1755.2003.00070.x
A randomized controlled trial of blood flow and stenosis surveillance of hemodialysis grafts
Abstract
Background: It is widely accepted that hemodialysis graft surveillance combined with correction of stenosis reduces thrombosis and prolongs graft survival. Nevertheless, few randomized controlled trials have evaluated this approach.
Methods: In this randomized controlled trial, 101 patients were assigned to control, flow (Qa), or stenosis groups, and were followed for up to 28 months. All patients had monthly Qa measured by ultrasound dilution and quarterly percent stenosis measured by duplex ultrasound. Referral for angiography was based on the following criteria: (1) control group (N = 34), clinical criteria; (2) flow group (N = 32), Qa <600 mL/min or clinical criteria; and (3) stenosis group (N = 35), stenosis>50% or clinical criteria. Stenosis >or=50% during angiography was corrected by preemptive percutaneous transluminal angioplasty (PTA).
Results: The preemptive PTA rate in the control group (0.22/patient year) was two thirds the rate in the flow group (0.34/patient year), and was highest in the stenosis group (0.65/patient year, P < 0.01). The percentage of grafts that thrombosed was similar in the control (47%) and flow groups (53%), but reduced in the stenosis group (29%, P = 0.10). Two-year graft survival was similar in the control (62%), flow (60%), and stenosis groups (64%) (P = 0.89).
Conclusion: Qa and stenosis surveillance were not associated with improved graft survival, although thrombosis was reduced in the stenosis group. The most important factors in this result may be that monthly Qa and quarterly stenosis measurements were not accurate or timely indicators of risk of thrombosis or progressive stenosis. This study does not support the concept that Qa or stenosis surveillance are superior to aggressive clinical monitoring.
Comment in
-
Failure to follow K/DOQI guidelines decreases effectiveness of access flow surveillance.Kidney Int. 2004 Jan;65(1):338-9; author reply 339. doi: 10.1111/j.1523-1755.2004.414_4.x. Kidney Int. 2004. PMID: 14675072 No abstract available.
-
Inadequate group size compromises conclusions of hemodialysis graft surveillance study.Kidney Int. 2004 Apr;65(4):1520-1; author reply 1521. doi: 10.1111/j.1523-1755.2004.555_4.x. Kidney Int. 2004. PMID: 15086500 No abstract available.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical