Plantar soft tissue loading under the medial metatarsals in the standing diabetic foot
- PMID: 12787987
- DOI: 10.1016/s1350-4533(03)00029-8
Plantar soft tissue loading under the medial metatarsals in the standing diabetic foot
Abstract
Diabetes mellitus (type 2) is the most frequent cause of non-traumatic lower-limb amputations. The major cause of impairment to the feet of diabetics is persistent hyperglycemia, potentially leading to peripheral neuropathy as well as to pathological changes in plantar soft tissue, which stiffen its structure and diminish its ability to effectively distribute foot-ground contact loads. In this study, a computational model of the foot structure in the standing position was utilized to evaluate stress distributions in plantar soft tissue under the medial metatarsal heads of simulated diabetic versus normal feet. The model comprises five anatomic planar cross-sections in the directions of the foot rays, which were solved for internal stresses under static ankle joint reaction (300 N) and triceps surae muscle forces (150 N) using the finite element method. Tissues were assumed to be homogenous, isotropic and elastic materials, with nonlinear stress-strain relations for the ligaments, fascia and plantar tissue. The model revealed significant tension stress concentrations (90-150 KPa) in the plantar pad of the simulated diabetic forefoot: they were four times the normal maximum stress under the first metatarsal head and almost eight times the normal maximum stress under the second metatarsal head. It was shown that with increased severity of stiffening of the plantar pad, as related to glucose-exposure, peak forefoot contact stresses may rise by 38 and 50% under the first and second metatarsal heads, respectively. The increase in averaged (von Mises) internal stresses within the plantar soft tissue is even more pronounced, and may rise by 82 and 307% for the tissue under the first and second metatarsal heads, respectively. These results, which conform to experimental data gathered over the last two decades, suggest that the process of injury in diabetic feet is very likely to initiate not on the skin surface, but in deeper tissue layers, and the tissues underlying the distal bony prominences of the medial metatarsals are the most vulnerable ones.
Similar articles
-
Three-dimensional finite element analysis of the foot during standing--a material sensitivity study.J Biomech. 2005 May;38(5):1045-54. doi: 10.1016/j.jbiomech.2004.05.035. J Biomech. 2005. PMID: 15797586
-
[Diffusion of ulcers in the diabetic foot is promoted by stiffening of plantar muscular tissue under excessive bone compression].Orthopade. 2004 Sep;33(9):999-1012. doi: 10.1007/s00132-004-0701-9. Orthopade. 2004. PMID: 15316602 German.
-
Clinical significance of musculoskeletal finite element model of the second and the fifth foot ray with metatarsal cavities and calcaneal sinus.Surg Radiol Anat. 2007 Oct;29(7):561-7. doi: 10.1007/s00276-007-0231-3. Epub 2007 Jul 10. Surg Radiol Anat. 2007. PMID: 17619812
-
Force, pressure, and motion measurements in the foot: current concepts.Clin Podiatr Med Surg. 1988 Jul;5(3):491-508. Clin Podiatr Med Surg. 1988. PMID: 3293751 Review.
-
Plantar pressures, plantar forces, and their influence on the pathogenesis of diabetic foot ulcers: a review.J Am Podiatr Med Assoc. 2013 Jul-Aug;103(4):322-32. doi: 10.7547/1030322. J Am Podiatr Med Assoc. 2013. PMID: 23878385 Review.
Cited by
-
Biomechanical Effects of Plastic Heel Cup on Plantar Fasciitis Patients Evaluated by Ultrasound Shear Wave Elastography.J Clin Med. 2022 Apr 12;11(8):2150. doi: 10.3390/jcm11082150. J Clin Med. 2022. PMID: 35456242 Free PMC article.
-
The compressive, shear, biochemical, and histological characteristics of diabetic and non-diabetic plantar skin are minimally different.J Biomech. 2021 Dec 2;129:110797. doi: 10.1016/j.jbiomech.2021.110797. Epub 2021 Oct 7. J Biomech. 2021. PMID: 34688066 Free PMC article.
-
FEM analysis in excellent cushion characteristic of ostrich (Struthio camelus) toe pads.PLoS One. 2019 May 22;14(5):e0216141. doi: 10.1371/journal.pone.0216141. eCollection 2019. PLoS One. 2019. PMID: 31116736 Free PMC article.
-
Motion characteristics of the medial and lateral longitudinal arch during landing.Eur J Appl Physiol. 2009 Feb;105(3):387-92. doi: 10.1007/s00421-008-0915-3. Epub 2008 Nov 8. Eur J Appl Physiol. 2009. PMID: 18998155
-
A novel diffusion tensor based three-dimensional constitutive model for human breast tissue.J Mech Behav Biomed Mater. 2025 Aug;168:106996. doi: 10.1016/j.jmbbm.2025.106996. Epub 2025 Apr 17. J Mech Behav Biomed Mater. 2025. PMID: 40262429
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical