Central venous catheter site care for blood and marrow transplant recipients
- PMID: 12793335
- DOI: 10.1188/03.CJON.289-298
Central venous catheter site care for blood and marrow transplant recipients
Abstract
Treatment-induced neutropenia, long central venous catheter (CVC) dwell times, and the use of immunosuppressive agents place blood and marrow transplant recipients at high risk for CVC infection. The most common causative organisms of CVC infection are ubiquitous skin flora of hospitalized patients. A great deal of research on CVC care, including dressing change procedures and frequency, has been conducted; however, variations in study design, patients studied, and terminology used to define CVC infection limit the generalizability of the findings. This article reviews significant studies of CVC care and infection rates and describes the findings of a survey of CVC care practices of Blood and Marrow Stem Cell Transplant Special Interest Group members of the Oncology Nursing Society.
Similar articles
-
Comparison of central venous catheter dressings in bone marrow transplant recipients.Oncol Nurs Forum. 1996 Jun;23(5):829-36. Oncol Nurs Forum. 1996. PMID: 8792352 Clinical Trial.
-
Comparison of two different time interval protocols for central venous catheter dressing in bone marrow transplant patients: results of a randomized, multicenter study. The Italian Nurse Bone Marrow Transplant Group (GITMO).Haematologica. 2000 Mar;85(3):275-9. Haematologica. 2000. PMID: 10702816 Clinical Trial.
-
[Comparison of two different protocols on change of medication in central venous catheterization in patients with bone marrow transplantation: results of a randomized multicenter study].Assist Inferm Ric. 2000 Apr-Jun;19(2):112-9. Assist Inferm Ric. 2000. PMID: 11107366 Clinical Trial. Italian.
-
Central venous catheters: preventing infection and occlusion.Br J Nurs. 1999 Aug 12-Sep 8;8(15):980-2, 984, 986-9. doi: 10.12968/bjon.1999.8.15.6524. Br J Nurs. 1999. PMID: 10711027 Review.
-
Transparent and gauze dressings and their effect on infection rates of central venous catheters: a review of past and current literature.J Intraven Nurs. 1996 Sep-Oct;19(5):240-5. J Intraven Nurs. 1996. PMID: 9060348 Review.
Cited by
-
Frequency of dressing changes for central venous access devices on catheter-related infections.Cochrane Database Syst Rev. 2016 Feb 1;2(2):CD009213. doi: 10.1002/14651858.CD009213.pub2. Cochrane Database Syst Rev. 2016. PMID: 26827714 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical