Abstract
Single-fiber EMG is a technique introduced in 1963 by Stålberg and Ekstedt for recording single muscle fiber action potentials by means of a specially constructed needle with a 25-microm recording surface. The needle is positioned in the muscle to record from two or more time-locked potentials belonging to the same motor unit. Jitter is the variability in the arrival time of action potentials to the recording electrode between consecutive discharges. This variability reflects end-plate conduction and is measured along with fiber density, which is the average number of fibers belonging to the same motor unit that is in the recording area. An abnormal test is one in which more than 10%, or the mean, of 20 fiber pairs has increased jitter when compared with normal reference values. Increased fiber density is seen with reinnervation. Single-fiber EMG is more sensitive than conventional EMG and is the most sensitive, but not specific, test for myasthenia gravis. Lambert-Eaton myasthenic syndrome, and other neuromusculasr junction pathology. It has been useful in the evaluation of some neuropathies and myopathies and has provided valuable information on the motor unit spatial arrangement, territory, microphysiology, and pathophysiology.
Similar articles
-
[Single-fibre electromyography].Rev Med Liege. 2004;59 Suppl 1:141-9. Rev Med Liege. 2004. PMID: 15244170 Review. French.
-
Single fiber electromyography.Handb Clin Neurol. 2019;160:303-310. doi: 10.1016/B978-0-444-64032-1.00019-9. Handb Clin Neurol. 2019. PMID: 31277856 Review.
-
AAEM minimonograph #25: single-fiber electromyography.Muscle Nerve. 1996 Sep;19(9):1069-83. doi: 10.1002/(SICI)1097-4598(199609)19:9<1069::AID-MUS1>3.0.CO;2-Y. Muscle Nerve. 1996. PMID: 8761262 Review.
-
[Single fiber electromyogram in myasthenia gravis and other neuromuscular diseases].Medicina (B Aires). 1991;51(4):307-14. Medicina (B Aires). 1991. PMID: 1668291 Spanish.
-
Single fiber electromyography and measuring jitter with concentric needle electrodes.Muscle Nerve. 2022 Aug;66(2):118-130. doi: 10.1002/mus.27573. Epub 2022 Jun 13. Muscle Nerve. 2022. PMID: 35694863
Cited by
-
Contribution of Single-Fiber Evaluation on Monitoring Outcomes Following Injection of Botulinum Toxin-A: A Narrative Review of the Literature.Toxins (Basel). 2021 May 17;13(5):356. doi: 10.3390/toxins13050356. Toxins (Basel). 2021. PMID: 34067540 Free PMC article. Review.
-
Prediction of organophosphorus insecticide-induced intermediate syndrome with stimulated concentric needle single fibre electromyography.PLoS One. 2018 Sep 27;13(9):e0203596. doi: 10.1371/journal.pone.0203596. eCollection 2018. PLoS One. 2018. PMID: 30261032 Free PMC article.
-
Time jitter of somatosensory evoked potentials in recovery from hypoxic-ischemic brain injury.J Neurosci Methods. 2011 Oct 15;201(2):355-60. doi: 10.1016/j.jneumeth.2011.08.025. Epub 2011 Aug 22. J Neurosci Methods. 2011. PMID: 21878352 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical