Quantitative sensory testing
- PMID: 12795516
- DOI: 10.1016/s1047-9651(02)00122-5
Quantitative sensory testing
Abstract
Quantitative sensory testing is a reliable way of assessing large and small sensory nerve fiber function. Sensory deficits may be quantified and the data used in parametric statistical analysis in research studies and drug trials. It is an important addition to the neurophysiologic armamentarium, because conventional sensory nerve conduction tests only the large fibers. QST is a psychophysical test and lacks the objectivity of NCS. The results are subject to changes owing to distraction, boredom, mental fatigue, drowsiness, or confusion. When patients are consciously or unconsciously biased toward an abnormal QST result, no psychophysical testing can reliably distinguish these patients from those with organic disease. QST tests the integrity of the entire sensory neuraxis and is of no localizing value. Dysfunction of the peripheral nerves or central nervous system may give rise to abnormalities in QST. As is true for other neurophysiologic tests, QST results should always be interpreted in light of the patient's clinical presentation. Quantitative sensory testing has been shown to be reasonably reproducible over a period of days or weeks in normal subjects. Because longitudinal QST studies of patients in drug trials are usually performed over a period of several months to a few years, reproducibility studies on the placebo-control group should be included. For individual patients, more studies are needed to determine the maximum allowable difference between two QSTs that can be attributed to experimental error. The reproducibility of thermal thresholds may not be as good as that of vibration threshold. Different commercially available QST instruments have different specifications (thermode size, stimulus characteristics), testing protocols, algorithms, and normal values. Only QST instruments and their corresponding methodologies that have been shown to be reproducible should be used for research and patient care. The data in the literature do not allow conclusions regarding the superiority of any QST instruments. The future of QST is promising; however, many factors can affect QST results. As is true for other neurophysiologic tests, QST is susceptible to many extraneous factors and to misuse when not properly interpreted by the clinician.
Similar articles
-
Technology literature review: quantitative sensory testing.Muscle Nerve. 2004 May;29(5):734-47. doi: 10.1002/mus.20053. Muscle Nerve. 2004. PMID: 15116380 Review.
-
Hand-arm vibration syndrome: clinical characteristics, conventional electrophysiology and quantitative sensory testing.Clin Neurophysiol. 2013 Aug;124(8):1680-8. doi: 10.1016/j.clinph.2013.01.025. Epub 2013 Mar 16. Clin Neurophysiol. 2013. PMID: 23507585
-
Neurological diagnosis--aspects of quantitative sensory testing methodology in relation to hand-arm vibration syndrome.Int Arch Occup Environ Health. 2002 Jan;75(1-2):68-77. doi: 10.1007/s004200100279. Int Arch Occup Environ Health. 2002. PMID: 11898879 Review.
-
Quantitative sensory testing cannot differentiate simulated sensory loss from sensory neuropathy.Neurology. 2003 Feb 11;60(3):465-70. doi: 10.1212/wnl.60.3.465. Neurology. 2003. PMID: 12578928 Clinical Trial.
-
Validation of a Brazilian quantitative sensory testing (QST) device for the diagnosis of small fiber neuropathies.Arq Neuropsiquiatr. 2011 Dec;69(6):943-8. doi: 10.1590/s0004-282x2011000700019. Arq Neuropsiquiatr. 2011. PMID: 22297885
Cited by
-
Reproducibility of a battery of human evoked pain models to detect pharmacological effects of analgesic drugs.Eur J Pain. 2019 Jul;23(6):1129-1140. doi: 10.1002/ejp.1379. Epub 2019 Apr 5. Eur J Pain. 2019. PMID: 30793411 Free PMC article.
-
Test-retest reliability of neurophysiological tests of hand-arm vibration syndrome in vibration exposed workers and unexposed referents.J Occup Med Toxicol. 2014 Nov 11;9(1):38. doi: 10.1186/s12995-014-0038-1. eCollection 2014. J Occup Med Toxicol. 2014. PMID: 25400687 Free PMC article.
-
The thermal sensation threshold and its reliability induced by the exposure to 28 GHz millimeter-wave.Front Neurosci. 2024 Feb 27;18:1331416. doi: 10.3389/fnins.2024.1331416. eCollection 2024. Front Neurosci. 2024. PMID: 38476868 Free PMC article.
-
A multi-modal evaluation of experimental pain and psychological function in women with carpometacarpal osteoarthritis.Osteoarthr Cartil Open. 2024 Aug 23;6(4):100515. doi: 10.1016/j.ocarto.2024.100515. eCollection 2024 Dec. Osteoarthr Cartil Open. 2024. PMID: 39286574 Free PMC article.
-
Early Intervention with Mepolizumab, Corticosteroids, and Intravenous Immunoglobulin for Dupilumab-Triggered Eosinophilic Granulomatosis with Polyangiitis: A Case Report.J Asthma Allergy. 2025 Apr 13;18:559-565. doi: 10.2147/JAA.S513640. eCollection 2025. J Asthma Allergy. 2025. PMID: 40248105 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials