Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 1992 Nov;15(11 Pt 2):2011-5.
doi: 10.1111/j.1540-8159.1992.tb03012.x.

Septal His-Purkinje ventricular pacing in canines: a new endocardial electrode approach

Affiliations

Septal His-Purkinje ventricular pacing in canines: a new endocardial electrode approach

P P Karpawich et al. Pacing Clin Electrophysiol. 1992 Nov.

Abstract

Ventricular activation sequences and cardiac performance are influenced by pacing sites. Stimulation of or close to the specialized atrioventricular (AV) conduction system optimizes paced ventricular function compared to alternative epi- or endocardial muscle conduction sites. This study reports a new endocardial electrode implant approach to approximate septal His-Purkinje ventricular pacing. Five 6-month-old beagles were used. A custom, platinum-iridium, exposed helical screw electrode (Medtronic, Inc.), 4.5-mm long, with a 17.8-mm2 surface area, was designed with a polyurethane covered 4 filar MP35N nickle conductor lead. An 8 French sheath (USCI, Inc.) was modified as introducer to permit simultaneous implant intracardiac pressure and electrogram recordings. Following a thoracotomy, the introducer was inserted through the right atrial appendage and advanced to record optimal His-bundle electrogram while maintaining atrial pressure along the septal tricuspid valve annulus. After electrode implant, ECG demonstrated narrow paced QRS morphology. Mean implant values showed sensed R wave 6.3 mV, slew rate 0.65 V/sec, pacing impedance 319 ohms, and threshold 0.9 V/3.3 mA at 0.5-msec output. Necropsy showed implant above the tricuspid annulus with electrode extension into and contained within the proximal ventricular septum. This study demonstrates that an endocardial septal approach to His-Purkinje ventricular pacing to optimize paced ventricular function is feasible with a new electrode design and precise septal implant technique. Alternative introducer designs may permit transvenous application of this approach.

PubMed Disclaimer

Comment in

LinkOut - more resources