Detection of lung cancer with volatile markers in the breath
- PMID: 12796197
- DOI: 10.1378/chest.123.6.2115
Detection of lung cancer with volatile markers in the breath
Abstract
Study objectives: To evaluate volatile organic compounds (VOCs) in the breath as tumor markers in lung cancer. Alkanes and monomethylated alkanes are oxidative stress products that are excreted in the breath, the catabolism of which may be accelerated by polymorphic cytochrome p450-mixed oxidase enzymes that are induced in patients with lung cancer.
Design: Combined case-control and cross-sectional study.
Setting: Five academic pulmonary medicine services in the United States and the United Kingdom.
Patients and participants: One hundred seventy-eight bronchoscopy patients and 41 healthy volunteers.
Intervention: Breath samples were analyzed by gas chromatography and mass spectroscopy to determine alveolar gradients (ie, the abundance in breath minus the abundance in room air) of C4-C20 alkanes and monomethylated alkanes.
Measurements: Patients with primary lung cancer (PLC) were compared to healthy volunteers, and a predictive model was constructed using forward stepwise discriminant analysis of the alveolar gradients. This model was cross-validated with a leave-one-out jackknife technique and was tested in two additional groups of patients who had not been used to develop the model (ie, bronchoscopy patients in whom cancer was not detected, and patients with metastatic lung cancer [MLC]).
Results: Eighty-seven of 178 patients had lung cancer (PLC, 67 patients; MLC, 15 patients; undetermined, 5 patients). A predictive model employing nine VOCs identified PLC with a sensitivity of 89.6% (60 of 67 patients) and a specificity of 82.9% (34 of 41 patients). On cross-validation, the sensitivity was 85.1% (57 of 67 patients) and the specificity was 80.5% (33 of 41 patients). The stratification of patients by tobacco smoking status, histologic type of cancer, and TNM stage of cancer revealed no marked effects. In the two additional tests, the model predicted MLC with a sensitivity of 66.7% (10 of 15 patients), and it classified the cancer-negative bronchoscopy patients with a specificity of 37.4% (34 of 91 patients).
Conclusions: Compared to healthy volunteers, patients with PLC had abnormal breath test findings that were consistent with the accelerated catabolism of alkanes and monomethylated alkanes. A predictive model employing nine of these VOCs exhibited sufficient sensitivity and specificity to be considered as a screen for lung cancer in a high-risk population such as adult smokers.
Comment in
-
To screen or not to screen: a volatile issue in lung cancer.Chest. 2003 Jun;123(6):1788-92. doi: 10.1378/chest.123.6.1788. Chest. 2003. PMID: 12796150 No abstract available.
Similar articles
-
Volatile markers of breast cancer in the breath.Breast J. 2003 May-Jun;9(3):184-91. doi: 10.1046/j.1524-4741.2003.09309.x. Breast J. 2003. PMID: 12752626
-
Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study.Lancet. 1999 Jun 5;353(9168):1930-3. doi: 10.1016/S0140-6736(98)07552-7. Lancet. 1999. PMID: 10371572
-
Prediction of lung cancer using volatile biomarkers in breath.Cancer Biomark. 2007;3(2):95-109. doi: 10.3233/cbm-2007-3204. Cancer Biomark. 2007. PMID: 17522431
-
Evidence of endogenous volatile organic compounds as biomarkers of diseases in alveolar breath.Ann Pharm Fr. 2013 Jul;71(4):203-15. doi: 10.1016/j.pharma.2013.05.002. Epub 2013 Jun 17. Ann Pharm Fr. 2013. PMID: 23835018 Review.
-
Analysis of volatile organic compounds in the exhaled breath for the diagnosis of lung cancer.J Thorac Oncol. 2008 Jul;3(7):774-80. doi: 10.1097/JTO.0b013e31817c7439. J Thorac Oncol. 2008. PMID: 18594325 Review.
Cited by
-
Piezoresistive Membrane Surface Stress Sensors for Characterization of Breath Samples of Head and Neck Cancer Patients.Sensors (Basel). 2016 Jul 22;16(7):1149. doi: 10.3390/s16071149. Sensors (Basel). 2016. PMID: 27455276 Free PMC article.
-
Advances in electronic-nose technologies developed for biomedical applications.Sensors (Basel). 2011;11(1):1105-76. doi: 10.3390/s110101105. Epub 2011 Jan 19. Sensors (Basel). 2011. PMID: 22346620 Free PMC article. Review.
-
Applications and advances in electronic-nose technologies.Sensors (Basel). 2009;9(7):5099-148. doi: 10.3390/s90705099. Epub 2009 Jun 29. Sensors (Basel). 2009. PMID: 22346690 Free PMC article.
-
Biosensors to Monitor Water Quality Utilizing Insect Odorant-Binding Proteins as Detector Elements.Biosensors (Basel). 2019 May 14;9(2):62. doi: 10.3390/bios9020062. Biosensors (Basel). 2019. PMID: 31091776 Free PMC article.
-
Diagnosis of head-and-neck cancer from exhaled breath.Br J Cancer. 2011 May 10;104(10):1649-55. doi: 10.1038/bjc.2011.128. Epub 2011 Apr 19. Br J Cancer. 2011. PMID: 21505455 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Miscellaneous