Fetal cerebral blood flow velocity during labor and the early neonatal period
- PMID: 12797144
- DOI: 10.1046/j.1469-0705.1994.04050372.x
Fetal cerebral blood flow velocity during labor and the early neonatal period
Abstract
This study was performed to elucidate circulatory changes in the fetal cerebral circulation during uncomplicated labor and in early neonatal life. Eighteen healthy term singleton fetuses were followed longitudinally during labor. Using the transabdominal approach, and the color Doppler technique, the middle cerebral artery was identified and Doppler flow velocity waveforms recorded between and during uterine contractions. Neonatal recordings were made by insonating the middle cerebral artery from the temporal region before and immediately after the cutting of the umbilical cord, and at 1 hour and 1 day after birth. The recorded Doppler signals were evaluated for pulsatility index, heart rate, peak systolic flow velocity, end-diastolic flow velocity and time-averaged maximum velocity. There was no change in the pulsatility index between and during contractions (1.39 +/- 0.36 and 1.40 +/- 0.39, respectively, mean +/- SD). A significant decrease in the pulsatility index compared to fetal values was seen 4 min after birth (1.06 +/- 0.30, p < 0.01). One hour after birth, the pulsatility index values increased significantly (1.52 +/- 0.25, p < 0.001), to fall again between I hour and 1 day after birth (0.95 +/- 0.26, p < 0.001). Mechanical compression of the skull, blood gas changes and a decrease in ductal shunting may all have contributed to these changes. The present study has shown physiological neonatal circulatory adaptation and onset of breathing to cause manifest changes in cerebral blood flow velocity.
Copyright 1994 International Society of Ultrasound in Obstetrics and Gynecology
Similar articles
-
Arterial Doppler ultrasound in 115 second- and third-trimester fetuses with congenital heart disease.Ultrasound Obstet Gynecol. 2001 May;17(5):398-402. doi: 10.1046/j.1469-0705.2001.00397.x. Ultrasound Obstet Gynecol. 2001. PMID: 11380963
-
First-trimester uteroplacental and fetal blood flow velocity waveforms in normally developing fetuses: a longitudinal study.Ultrasound Obstet Gynecol. 1994 Jul 1;4(4):284-8. doi: 10.1046/j.1469-0705.1994.04040284.x. Ultrasound Obstet Gynecol. 1994. PMID: 12797162
-
Nitric oxide donors in pregnancy: fetomaternal hemodynamic effects induced in mild pre-eclampsia and threatened preterm labor.Ultrasound Obstet Gynecol. 1999 Aug;14(2):101-9. doi: 10.1046/j.1469-0705.1999.14020101.x. Ultrasound Obstet Gynecol. 1999. PMID: 10492869
-
Relationship between arterial and venous Doppler and perinatal outcome in fetal growth restriction.Ultrasound Obstet Gynecol. 2000 Oct;16(5):407-13. doi: 10.1046/j.1469-0705.2000.00284.x. Ultrasound Obstet Gynecol. 2000. PMID: 11169323
-
Assessment of fetal cerebral arterial and venous blood flow before and after vaginal delivery or Cesarean section.Ultrasound Obstet Gynecol. 2004 Oct;24(5):522-8. doi: 10.1002/uog.1749. Ultrasound Obstet Gynecol. 2004. PMID: 15459931
Cited by
-
Lost in Transition: A Systematic Review of Neonatal Electroencephalography in the Delivery Room-Are We Forgetting an Important Biomarker for Newborn Brain Health?Front Pediatr. 2017 Aug 10;5:173. doi: 10.3389/fped.2017.00173. eCollection 2017. Front Pediatr. 2017. PMID: 28848727 Free PMC article. Review.
-
Changes in cerebral oxygenation during early postnatal adaptation in newborns delivered by vacuum extraction measured by near-infrared spectroscopy.BMC Pediatr. 2014 Jan 27;14:21. doi: 10.1186/1471-2431-14-21. BMC Pediatr. 2014. PMID: 24467703 Free PMC article.
-
Enhanced Monitoring of the Preterm Infant during Stabilization in the Delivery Room.Front Pediatr. 2016 Mar 31;4:30. doi: 10.3389/fped.2016.00030. eCollection 2016. Front Pediatr. 2016. PMID: 27066463 Free PMC article. Review.
LinkOut - more resources
Full Text Sources