Upstaging of atypical ductal hyperplasia after vacuum-assisted 11-gauge stereotactic core needle biopsy
- PMID: 12799332
- DOI: 10.1001/archsurg.138.6.619
Upstaging of atypical ductal hyperplasia after vacuum-assisted 11-gauge stereotactic core needle biopsy
Abstract
Background: Nonpalpable mammographic abnormalities are frequently evaluated by means of a stereotactic core needle biopsy. This technique is a very sensitive indicator of invasive cancer, but is less reliable to discriminate between ductal carcinoma in situ and atypical ductal hyperplasia (ADH). The objective of this study was to determine the correlation of the 11-gauge vacuum-assisted core needle biopsy to open biopsy when a diagnosis of ADH is obtained.
Hypothesis: The use of 11-gauge vacuum-assisted stereotactic core needle biopsy does not conclusively diagnose ADH.
Design: Retrospective analysis.
Setting: University-affiliated teaching hospital.
Patients: Mammographic findings were evaluated with an 11-gauge vacuum-assisted stereotactic core biopsy in 1750 patients. Seventy-seven patients were diagnosed as having ADH; of these, 65 underwent excisional biopsy.
Main outcome measures: Pathological upstaging rate.
Results: Of the 65 patients who underwent excisional breast biopsy, 11 (17%) had their condition upstaged to a breast cancer diagnosis. These patients had presented at a later age than those who retained a benign diagnosis after excisional biopsy. The number of cores taken did not correlate with diagnostic accuracy.
Conclusions: Of the 65 patients who underwent open biopsy for ADH in this series, only 83% had an accurate diagnosis. A diagnosis of ADH by stereotactic core needle biopsy should be followed by an open excisional biopsy.
Similar articles
-
Is surgical excision necessary for focal atypical ductal hyperplasia found at stereotactic vacuum-assisted breast biopsy?Ann Surg Oncol. 2008 Nov;15(11):3232-8. doi: 10.1245/s10434-008-0100-2. Epub 2008 Aug 12. Ann Surg Oncol. 2008. PMID: 18696163
-
Atypical ductal hyperplasia: improved accuracy with the 11-gauge vacuum-assisted versus the 14-gauge core biopsy needle.Ann Surg Oncol. 2007 Sep;14(9):2497-501. doi: 10.1245/s10434-007-9454-0. Epub 2007 Jun 13. Ann Surg Oncol. 2007. PMID: 17564749
-
Comparison of the diagnostic accuracy of a vacuum-assisted percutaneous intact specimen sampling device to a vacuum-assisted core needle sampling device for breast biopsy: initial experience.Breast J. 2006 Jul-Aug;12(4):302-8. doi: 10.1111/j.1075-122X.2006.00268.x. Breast J. 2006. PMID: 16848839
-
False-negative diagnoses at stereotactic vacuum-assisted needle breast biopsy: long-term follow-up of 1,280 lesions and review of the literature.AJR Am J Roentgenol. 2009 Feb;192(2):341-51. doi: 10.2214/AJR.08.1127. AJR Am J Roentgenol. 2009. PMID: 19155393 Review.
-
Factors affecting the under-diagnosis of atypical ductal hyperplasia diagnosed by core needle biopsies - A 10-year retrospective study and review of the literature.Int J Surg. 2018 Jan;49:27-31. doi: 10.1016/j.ijsu.2017.11.005. Epub 2017 Nov 13. Int J Surg. 2018. PMID: 29146271 Review.
Cited by
-
Atypical ductal hyperplasia bordering on DCIS on core biopsy is associated with higher risk of upgrade than conventional atypical ductal hyperplasia.Breast Cancer Res Treat. 2020 Dec;184(3):873-880. doi: 10.1007/s10549-020-05890-1. Epub 2020 Aug 28. Breast Cancer Res Treat. 2020. PMID: 32857242 Free PMC article.
-
The effect of delay of excisional biopsy on upstage rate for atypical ductal hyperplasia, flat epithelial atypia, intraductal papilloma, and radial scar.Breast Cancer Res Treat. 2022 Dec;196(3):527-534. doi: 10.1007/s10549-022-06745-7. Epub 2022 Oct 1. Breast Cancer Res Treat. 2022. PMID: 36181604 Free PMC article.
-
The ratio of atypical ductal hyperplasia foci to core numbers in needle biopsy: a practical index predicting breast cancer in subsequent excision.Korean J Pathol. 2012 Feb;46(1):15-21. doi: 10.4132/KoreanJPathol.2012.46.1.15. Epub 2012 Feb 23. Korean J Pathol. 2012. PMID: 23109973 Free PMC article.
-
Performance Benchmark Metrics and Clinicopathologic Outcomes of MRI-Guided Breast Biopsies: A Systematic Review and Meta-Analysis.Eur J Breast Health. 2023 Jan 1;19(1):1-27. doi: 10.4274/ejbh.galenos.2022.2022-12-1. eCollection 2023 Jan. Eur J Breast Health. 2023. PMID: 36605469 Free PMC article.
-
Diagnostic accuracy of core biopsy for ductal carcinoma in situ and its implications for surgical practice.J Clin Pathol. 2006 Jul;59(7):740-3. doi: 10.1136/jcp.2005.034330. J Clin Pathol. 2006. PMID: 16803949 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical