Independent calculations to validate monitor units from ADAC treatment planning system
- PMID: 12804704
- DOI: 10.1016/S0958-3947(02)00237-6
Independent calculations to validate monitor units from ADAC treatment planning system
Abstract
Current standards of practice are based on the use of an independent calculation to validate the monitor units (MUs) derived from a treatment planning system. The ADAC PINNACLE treatment planning system has shown discrepancies of 10% or more compared to simple independent calculations for highly contoured areas such as tangential breast and chest wall irradiation. The ADAC treatment planning system generally requires more MUs to deliver the same prescribed dose. Independent MU calculation methods are based on full phantom conditions. On the other hand, the MUs from the ADAC treatment planning system are derived using realistic phantom scatter. As such, differences exist in TMR factors, off-axis wedge factors, and the phantom scatter factor. To systematically study the discrepancies due to phantom conditions, experimental measurements were performed with various percentages of tissue missing. The agreement between the experimental measurements and ADAC calculations was found to be within 2%. Using breast field geometry, a relationship between missing tissue and the dosimetric parameters used by ADAC was developed. This relationship, when applied, yielded independent MU calculations whose values closely matched those from the ADAC treatment planning system.
Similar articles
-
Comparison of monitor units calculated by radiotherapy treatment planning system and an independent monitor unit verification software.Phys Med. 2011 Jan;27(1):21-9. doi: 10.1016/j.ejmp.2010.01.006. Epub 2010 Feb 20. Phys Med. 2011. PMID: 20172756
-
Measurements of primary off-axis ratios in wedged asymmetric photon fields: a formalism for dose and monitor unit calculations.Phys Med Biol. 2005 May 7;50(9):2003-14. doi: 10.1088/0031-9155/50/9/006. Epub 2005 Apr 13. Phys Med Biol. 2005. PMID: 15843733
-
Patient-specific IMRT verification using independent fluence-based dose calculation software: experimental benchmarking and initial clinical experience.Phys Med Biol. 2007 Aug 21;52(16):4981-92. doi: 10.1088/0031-9155/52/16/018. Epub 2007 Aug 1. Phys Med Biol. 2007. PMID: 17671348
-
[Is there a future for dosimetry control by portal imaging?].Cancer Radiother. 2000 Nov;4 Suppl 1:36s-43s. Cancer Radiother. 2000. PMID: 11194963 Review. French.
-
In vivo dosimetry during tangential breast treatment.Radiother Oncol. 1991 Dec;22(4):269-79. doi: 10.1016/0167-8140(91)90162-a. Radiother Oncol. 1991. PMID: 1792320 Review.
Cited by
-
Verifying monitor unit calculations for tangential breast fields.J Appl Clin Med Phys. 2006 May 25;7(2):50-7. doi: 10.1120/jacmp.v7i2.2177. J Appl Clin Med Phys. 2006. PMID: 17533323 Free PMC article.
-
Independent dose verification for brain stereotactic radiotherapy using different add-on micro multi-leaf collimators.Radiol Phys Technol. 2017 Sep;10(3):286-293. doi: 10.1007/s12194-017-0398-1. Epub 2017 Apr 19. Radiol Phys Technol. 2017. PMID: 28425084
-
Verifying monitor unit calculations for tangential whole breast fields in 3-dimensional planning.J Appl Clin Med Phys. 2008 Jan 28;9(1):47-53. doi: 10.1120/jacmp.v9i1.2713. J Appl Clin Med Phys. 2008. PMID: 18449165 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials