Frequency-doubling technology perimetry
- PMID: 12809159
- DOI: 10.1016/s0896-1549(03)00011-7
Frequency-doubling technology perimetry
Abstract
The FDT perimeter is a compact and relatively inexpensive perimeter whose transportability, tolerance to refractive errors, and rapid test times (less than 1 minute per eye) make it a suitable candidate for visual field screening. It is a uniform finding that the C-20-1 screening protocol of the FDT perimeter provides good sensitivity and specificity for the detection of moderate and severe losses in glaucoma. Sensitivity can be increased by use of the C-20-5 screening protocol. In addition, the FDT perimeter demonstrates good sensitivity and specificity for detecting the presence of neuro-ophthalmic disorders, though it may have a limited ability to determine whether a field defect is hemianopic. There is only limited evidence that the FDT can appropriately detect retinal disease. Despite some evidence that the current FDT perimeter may be suitable for staging and monitoring the progression of visual field damage, the large targets used in the test make this of limited practicability. The development of a frequency-doubling test with smaller targets spaced over narrower intervals would improve the ability of FDT perimetry to determine the spatial extent of visual field defects.
Similar articles
-
Sensitivity and specificity of frequency doubling perimetry in neuro-ophthalmic disorders: a comparison with conventional automated perimetry.Invest Ophthalmol Vis Sci. 2002 Apr;43(4):1277-83. Invest Ophthalmol Vis Sci. 2002. PMID: 11923276
-
Frequency-doubling technology perimetry for detection of the development of visual field defects in glaucoma suspect eyes: a prospective study.JAMA Ophthalmol. 2014 Jan;132(1):77-83. doi: 10.1001/jamaophthalmol.2013.5511. JAMA Ophthalmol. 2014. PMID: 24177945
-
Role of frequency doubling perimetry in detecting neuro-ophthalmic visual field defects.Am J Ophthalmol. 2001 Jun;131(6):734-41. doi: 10.1016/s0002-9394(01)00837-6. Am J Ophthalmol. 2001. PMID: 11384569
-
[Frequency-doubling technology : A new method for determining glaucomatous visual field defects].Ophthalmologe. 2009 Aug;106(8):709-13. doi: 10.1007/s00347-009-1957-6. Ophthalmologe. 2009. PMID: 19652980 Review. German.
-
Frequency doubling technology perimetry for the detection of glaucomatous visual field loss.Am J Ophthalmol. 2000 Mar;129(3):376-8. doi: 10.1016/s0002-9394(00)00352-4. Am J Ophthalmol. 2000. PMID: 10755955 Review. No abstract available.
Cited by
-
Functional assessment of magno, parvo and konio-cellular pathways; current state and future clinical applications.J Ophthalmic Vis Res. 2011 Apr;6(2):119-26. J Ophthalmic Vis Res. 2011. PMID: 22454721 Free PMC article.
-
Visual contrast sensitivity in Alzheimer's disease, mild cognitive impairment, and older adults with cognitive complaints.Neurobiol Aging. 2013 Apr;34(4):1133-44. doi: 10.1016/j.neurobiolaging.2012.08.007. Epub 2012 Oct 18. Neurobiol Aging. 2013. PMID: 23084085 Free PMC article.
-
Long-Term Structural and Functional Assessment of Doyne Honeycomb Retinal Dystrophy following Nanosecond 2RT Laser Treatment: A Case Series.Case Rep Ophthalmol. 2023 Nov 23;14(1):626-639. doi: 10.1159/000534579. eCollection 2023 Jan-Dec. Case Rep Ophthalmol. 2023. PMID: 38023612 Free PMC article.
-
Line bisection in Parkinson's disease: investigation of contributions of visual field, retinal vision, and scanning patterns to visuospatial function.Behav Neurosci. 2013 Apr;127(2):151-63. doi: 10.1037/a0031618. Epub 2013 Jan 28. Behav Neurosci. 2013. PMID: 23356329 Free PMC article.
-
Diffusion tensor imaging for in vivo detection of degenerated optic radiation.ISRN Ophthalmol. 2011 Dec 27;2011:648450. doi: 10.5402/2011/648450. eCollection 2011. ISRN Ophthalmol. 2011. PMID: 24533184 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources