Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2003 Jun;7(2):85-8.
doi: 10.1007/s10029-003-0116-2. Epub 2003 Feb 25.

Ultrasound detection of visceral adhesion after intraperitoneal ventral hernia treatment: a comparative study of protected versus unprotected meshes

Affiliations
Comparative Study

Ultrasound detection of visceral adhesion after intraperitoneal ventral hernia treatment: a comparative study of protected versus unprotected meshes

J P Arnaud et al. Hernia. 2003 Jun.

Erratum in

  • Hernia. 2003 Sep;7(3):164

Abstract

Intraperitoneal (IP) ventral hernia repair has been proposed with the advantages of reducing dissection, operative time, and postoperative pain. The IP position of the mesh is suspected of increasing the risk of visceral adhesion and inducing complications. To overcome these drawbacks, a mesh protected on one side by a hydrophilic resorbable film (Parietex Composite) has been validated. Using a previously described ultrasound procedure, the purpose of this study was to compare the rate of visceral adhesion after intraperitoneal placement of a polyester mesh versus this protected mesh. Fifty-one patients who received a Parietex Composite mesh were prospectively compared to a retrospective series of 22 consecutive asymptomatic patients who received a Mersilene mesh. To objectively assess visceral adhesion toward the abdominal wall, an ultrasound (US) specific examination was firstly validated and secondly used to evaluate the adhesion incidence in both groups. Both groups were equivalent in terms of inclusion criteria and body mass index (BMI). Pre-operative US versus perioperative macroscopical findings determined the following parameters: sensitivity 83%, accuracy 78%, negative predictive value 81%. Using this procedure, 77% of the patients exhibited visceral adhesion to the mesh in the Mersilene group, against 18% in the Parietex Composite group (P<0.001, chi-square). US examination represents a suitable tool to evaluate postoperative adhesions to the abdominal wall. Using this procedure, a significant reduction of visceral adhesion in the Parietex Composite group was shown.

PubMed Disclaimer

References

    1. Am J Surg. 1977 Mar;133(3):338-45 - PubMed
    1. J Surg Res. 1997 Mar;68(2):126-32 - PubMed
    1. Fertil Steril. 1994 Feb;61(2):219-35 - PubMed
    1. Surgery. 1995 Jun;117(6):663-9 - PubMed
    1. Ann Chir. 1995;49(6):539-42; discussion 542-3 - PubMed

Publication types

MeSH terms

LinkOut - more resources