Monitoring of human immunodeficiency virus infection in resource-constrained countries
- PMID: 12822129
- DOI: 10.1086/375369
Monitoring of human immunodeficiency virus infection in resource-constrained countries
Abstract
The reference standards used to monitor human immunodeficiency virus (HIV) infection are flow cytometric analysis of T lymphocyte subsets to provide the CD4+ T cell count and molecular assays to quantify plasma HIV load. Few laboratories in resource-constrained countries can afford to perform these tests. A number of lower-cost assays requiring less expensive equipment may be well-suited to such countries. These include manual CD4 cell assays (Dynal, Coulter, BioRad) and ultrasensitive reverse transcriptase (Cavidi) and p24 (Perkin Elmer Life Sciences) assays to monitor virus load. Quality control and access to quality assurance programs are essential. The total lymphocyte count, although readily available and inexpensive, generally does not correlate as closely with CD4+ T cell counts. Other surrogate markers, such as beta2-microglobulin, are not suitable for routine monitoring of HIV infection. This review discusses the above assays and their role in addition to clinical monitoring in resource-constrained countries.
Similar articles
-
Low-cost monitoring of HIV infected individuals on highly active antiretroviral therapy (HAART) in developing countries.Indian J Med Res. 2005 Apr;121(4):345-55. Indian J Med Res. 2005. PMID: 15817948 Review.
-
Can routine clinical markers be used longitudinally to monitor antiretroviral therapy success in resource-limited settings?Clin Infect Dis. 2007 Jan 1;44(1):135-8. doi: 10.1086/510072. Epub 2006 Nov 28. Clin Infect Dis. 2007. PMID: 17143829
-
Total lymphocyte count as a possible surrogate of CD4 cell count to prioritize eligibility for antiretroviral therapy among HIV-infected individuals in resource-limited settings.Antivir Ther. 2003 Oct;8(5):379-84. Antivir Ther. 2003. PMID: 14640384
-
Residual viraemia in HIV-1-infected patients with plasma viral load <or=20 copies/ml is associated with increased blood levels of soluble immune activation markers.Scand J Immunol. 2008 Dec;68(6):652-60. doi: 10.1111/j.1365-3083.2008.02184.x. Scand J Immunol. 2008. PMID: 19055701
-
The measurement of HIV-1 viral load in resource-limited settings: how and where?Clin Lab. 2007;53(3-4):135-48. Clin Lab. 2007. PMID: 17447649 Review.
Cited by
-
Microflow cytometers with integrated hydrodynamic focusing.Sensors (Basel). 2013 Apr 9;13(4):4674-93. doi: 10.3390/s130404674. Sensors (Basel). 2013. PMID: 23571670 Free PMC article.
-
Low-cost assays for monitoring HIV infected individuals in resource-limited settings.Indian J Med Res. 2011 Dec;134(6):823-34. doi: 10.4103/0971-5916.92628. Indian J Med Res. 2011. PMID: 22310816 Free PMC article. Review.
-
Comparison of capillary based microflurometric assay for CD4+ T cell count estimation with dual platform Flow cytometry.AIDS Res Ther. 2006 Oct 16;3:26. doi: 10.1186/1742-6405-3-26. AIDS Res Ther. 2006. PMID: 17042936 Free PMC article.
-
Enhancing the performance of a point-of-care CD4+ T-cell counting microchip through monocyte depletion for HIV/AIDS diagnostics.Lab Chip. 2009 May 21;9(10):1357-64. doi: 10.1039/b818813k. Epub 2009 Feb 4. Lab Chip. 2009. PMID: 19417901 Free PMC article.
-
HPTN 062: a feasibility and acceptability pilot intervention to reduce HIV transmission risk behaviors among individuals with acute and early HIV infection in Lilongwe, Malawi.AIDS Behav. 2014 Sep;18(9):1785-800. doi: 10.1007/s10461-014-0707-1. AIDS Behav. 2014. PMID: 24523007 Free PMC article. Clinical Trial.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources
Medical
Research Materials