Prevention of latex allergy among health care workers: evaluation of the extractable latex protein content in different types of medical gloves
- PMID: 12822132
- DOI: 10.1002/ajim.10232
Prevention of latex allergy among health care workers: evaluation of the extractable latex protein content in different types of medical gloves
Abstract
Background: Since the 1980s, there has been increased use of latex gloves by health care workers and a concomitant increase of irritant and allergic reactions. The total protein content and the latex allergenic protein content in different types of medical gloves commonly used in our hospital were evaluated to acquire information useful for preventing latex allergy in our hospital personnel.
Methods: The total protein content and the allergic latex protein contents were evaluated with Lowry modified method and RAST inhibition assay in samples and extracts of 29 different types of medical gloves.
Results: The highest concentrations of total proteins and allergenic latex proteins were found in examination powdered latex gloves and in surgical powdered latex gloves; a significant amount of latex proteins was found in some brands of nitrile gloves.
Conclusions: The clear association between the total protein levels and the allergenic latex protein levels suggests that the gloves with highest total protein content have the greatest allergenic potential. Therefore, it is recommended that manufacturing companies should provide package inserts including the total protein contents and possibly allergenic latex protein levels. They should declare whether they have added latex to their nitrile glove formulation. RAST-inhibition assays directly on glove samples instead of glove extract seems to be a good reliable and faster alternative for the evaluation of the allergenic potential of latex gloves.
Copyright 2003 Wiley-Liss, Inc.
Similar articles
-
[Protein content of latex gloves used in hospitals].G Ital Med Lav Ergon. 2002 Oct-Dec;24(4):441-3. G Ital Med Lav Ergon. 2002. PMID: 12528352 Italian.
-
[Latex allergy in health care workers: frequency, exposure quantification, efficacy of criteria used for job fitness assessment].Med Lav. 2004 Jan-Feb;95(1):62-71. Med Lav. 2004. PMID: 15112749 Italian.
-
The en 455-3 modified lowry assay does not yield a reliable estimate of the allergenicity level of latex gloves with low total protein content.Med Sci Monit. 2004 Jul;10(7):PI81-6. Epub 2004 Jun 29. Med Sci Monit. 2004. PMID: 15232516
-
[Prevention of work-related latex allergy].Tidsskr Nor Laegeforen. 1998 Sep 10;118(21):3287-92. Tidsskr Nor Laegeforen. 1998. PMID: 9772818 Review. Norwegian.
-
[Consensus Document. Update on latex exposure and use of gloves in Italian health care settings].Med Lav. 2008 Sep-Oct;99(5):387-99. Med Lav. 2008. PMID: 18828538 Italian.
Cited by
-
Prevention of latex allergy among health care workers and in the general population: latex protein content in devices commonly used in hospitals and general practice.Int Arch Occup Environ Health. 2006 Aug;79(7):550-7. doi: 10.1007/s00420-005-0080-5. Epub 2006 Feb 9. Int Arch Occup Environ Health. 2006. PMID: 16468057
-
Reduced protein levels in latex gloves may play an alternative approach to lowering latex sensitization risks among health workers; a cross-sectional analytical study.J Occup Med Toxicol. 2024 Jun 3;19(1):21. doi: 10.1186/s12995-024-00420-x. J Occup Med Toxicol. 2024. PMID: 38825689 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical