[Comparison of two 27-G-caliber needles for spinal anesthesia. Study of 1,555 patients]
- PMID: 12825306
[Comparison of two 27-G-caliber needles for spinal anesthesia. Study of 1,555 patients]
Abstract
Objectives: The purpose of this study was to compare two 27-gauge anesthesia needles with different points (a Whitacre-type point and a Quincke-type point) and to assess the incidences of postdural puncture headache (PDPH), puncture difficulty and failed anesthesia.
Material and methods: This prospective, randomized and double-blind trial enrolled 1,555 patients receiving spinal anesthesia for lower abdominal surgery. No age limits were established. A 27-gauge Whitacre-point needle was used in group I (n = 748) and a 27-gauge Quincke-point needle was used in group II (n = 774).
Results: The incidences of PDPH were significantly different in groups I (0.53%) and II (1.85%) (p < 0.01). Puncture was easy in 84.89% of the procedures in group I and in 78.81% in group II (p < 0.01). The number of cases in which a puncture could not be accomplished was similar in the two groups (2.41% in group I and 2.07% in group II). The number of failed anesthetic procedures was also similar (0.96% in group I and 1.45% in group II).
Conclusions: When a 27-gauge Whitacre-point needle is used, fewer cases of PDPH develop and the puncture is easier to accomplish than when a Quincke-point needle is used. The number of failed anesthetic procedures is similar with both needles. Whitacre-point 27-gauge needles are preferable to Quincke-point 27-gauge needles.
Similar articles
-
PDPH in obstetric anesthesia: comparison of 24-gauge Sprotte and 25-gauge Quincke needles and effect of subarachnoid administration of fentanyl.Reg Anesth. 1993 Jul-Aug;18(4):222-5. Reg Anesth. 1993. PMID: 8398955 Clinical Trial.
-
Postdural puncture headache: comparison of 25-gauge Whitacre and Quincke needles.Reg Anesth. 1993 May-Jun;18(3):166-9. Reg Anesth. 1993. PMID: 8323889 Clinical Trial.
-
Comparison of 27-gauge (0.41-mm) Whitacre and Quincke spinal needles with respect to post-dural puncture headache and non-dural puncture headache.Acta Anaesthesiol Scand. 2004 Apr;48(4):474-9. doi: 10.1111/j.0001-5172.2004.00345.x. Acta Anaesthesiol Scand. 2004. PMID: 15025611 Clinical Trial.
-
[Comparison of efficacy and complications of 27G and 29G Sprottte needles for subarachnoid anesthesia].Rev Esp Anestesiol Reanim. 2002 Nov;49(9):448-54. Rev Esp Anestesiol Reanim. 2002. PMID: 12516488 Review. Spanish.
-
Finer gauge of cutting but not pencil-point needles correlate with lower incidence of post-dural puncture headache: a meta-regression analysis.J Anesth. 2016 Oct;30(5):855-63. doi: 10.1007/s00540-016-2221-2. Epub 2016 Jul 28. J Anesth. 2016. PMID: 27468735 Review.
Cited by
-
Needle gauge and tip designs for preventing post-dural puncture headache (PDPH).Cochrane Database Syst Rev. 2017 Apr 7;4(4):CD010807. doi: 10.1002/14651858.CD010807.pub2. Cochrane Database Syst Rev. 2017. PMID: 28388808 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Medical