Implant-retained mandibular overdentures with immediate loading: a 3- to 8-year prospective study on 328 implants
- PMID: 12831726
- DOI: 10.1111/j.1708-8208.2003.tb00179.x
Implant-retained mandibular overdentures with immediate loading: a 3- to 8-year prospective study on 328 implants
Abstract
Purpose: The purpose of this study is to evaluate prospectively survival and success rates of implants placed in the interforaminal area of edentulous mandibles and immediately loaded with an implant-supported overdenture.
Materials and methods: Eighty-two patients, 33 males and 49 females, aged between 42 and 87 years (mean age 58.6 yr), presenting edentulous mandibles were rehabilitated with an implant-supported overdenture in the mandible. Three hundred twenty-eight screw-type osseointegrated implants (164 Ha-Ti, Mathys Dental, Bettlach, Switzerland; 84 ITI Dental Implant System, Straumann Institute, Waldenburg, Switzerland; 40 Brånemark Conical, Nobel Biocare AB, Gothenburg, Sweden; 40 Frialoc, Friatec, AG Mannheiti, Germany), were placed in the intraforaminal area of the mental symphysis (4 implants per patient). Immediately after implant placement, a U-shaped gold or titanium bar was fabricated and implants were rigidly connected with the bar and immediately loaded with an implant-retained overdenture. Success rate of implants was evaluated clinically and radiographically every year after the loading of the prostheses according to the following parameters: (1) absence of clinical mobility of implants tested individually after bar removal, (2) absence of periimplant radiolucency evaluated on panoramic radiographs, (3) absence of pain and radiologic or clinical signs of neural lesion, and (4) periimplant bone resorption mesial and distal to each implant less than 0.2 mm after the first year of prosthetic load.
Results: Of 328 implants placed, 296 were followed up from a minimum of 36 months to a maximum of 96 months, with a mean follow-up of 62 months. Seven implants in 6 different patients were removed owing to loss of osseointegration, whereas 18 implants, although still osseointegrated, did not fulfill success criteria due to bone resorption > 0.2 mm/year after the first year of loading. Despite implant losses, all patients maintained their bars supporting overdentures, although in 6 patients they were supported by 3 instead of 4 implants. The only patient who lost 2 implants received 2 new implants, which survived normally. Therefore, the absolute success and survival rates were 91.6% and 97.6%, respectively, whereas the cumulative survival and success rates of implants obtained with a life table analysis were 96.1% and 88.2%, respectively.
Conclusions: Results of this study seem to demonstrate that survival and success rates of immediately loaded implants placed in the intraforaminal area of the mandible and rigidly connected with a bar through an implant-supported overdenture are consistent with those reported in the international literature as far as delayed loading is concerned after 3 years of loading. After longer observation times, this study demonstrated that, while survival rates of implants and bar-supported overdentures are still consistent with results published in the international literature pertaining to delayed loading, a moderate decrease in success rates of implants was found. Nevertheless, it must be stressed that this decrease (88.8 and 90.4% after a 7- to 8-year observation period for Ha-Ti and ITI implants) is related only to two implant systems; no data are available for the other two implant systems because of the shorter follow-up period.
Similar articles
-
Effects of immediate and delayed loading protocols on marginal bone loss around implants in unsplinted mandibular implant-retained overdentures: a systematic review and meta-analysis.BMC Oral Health. 2021 Mar 17;21(1):122. doi: 10.1186/s12903-021-01486-3. BMC Oral Health. 2021. PMID: 33731092 Free PMC article.
-
Immediate loading of Brånemark implants: a 24-month follow-up of a comparative prospective pilot study between mandibular overdentures supported by Conical transmucosal and standard MK II implants.Clin Implant Dent Relat Res. 2002;4(4):190-9. doi: 10.1111/j.1708-8208.2002.tb00171.x. Clin Implant Dent Relat Res. 2002. PMID: 12685794 Clinical Trial.
-
Implant-retained mandibular overdentures with immediate loading. A retrospective multicenter study on 226 consecutive cases.Clin Oral Implants Res. 1997 Feb;8(1):48-57. doi: 10.1111/j.1600-0501.1997.tb00007.x. Clin Oral Implants Res. 1997. PMID: 9586456
-
3-year prospective multicenter study on one-stage implant surgery and early loading in the edentulous mandible.Clin Implant Dent Relat Res. 2003;5(1):39-46. doi: 10.1111/j.1708-8208.2003.tb00180.x. Clin Implant Dent Relat Res. 2003. PMID: 12831727 Clinical Trial.
-
Loading protocols for implant-supported overdentures in the edentulous jaw: a systematic review and meta-analysis.Int J Oral Maxillofac Implants. 2014;29 Suppl:271-86. doi: 10.11607/jomi.2014suppl.g4.4. Int J Oral Maxillofac Implants. 2014. PMID: 24660203
Cited by
-
Effects of immediate and delayed loading protocols on marginal bone loss around implants in unsplinted mandibular implant-retained overdentures: a systematic review and meta-analysis.BMC Oral Health. 2021 Mar 17;21(1):122. doi: 10.1186/s12903-021-01486-3. BMC Oral Health. 2021. PMID: 33731092 Free PMC article.
-
Improved Osteoblast and Chondrocyte Adhesion and Viability by Surface-Modified Ti6Al4V Alloy with Anodized TiO₂ Nanotubes Using a Super-Oxidative Solution.Materials (Basel). 2015 Mar 2;8(3):867-883. doi: 10.3390/ma8030867. Materials (Basel). 2015. PMID: 28787976 Free PMC article.
-
A Non-Interventional Study Documenting Use and Success of Tissue Level Implants.Int J Environ Res Public Health. 2020 Jul 4;17(13):4816. doi: 10.3390/ijerph17134816. Int J Environ Res Public Health. 2020. PMID: 32635445 Free PMC article.
-
Geriatric slim implants for complete denture wearers: clinical aspects and perspectives.Clin Cosmet Investig Dent. 2013 Aug 28;5:63-8. doi: 10.2147/CCIDE.S47743. eCollection 2013. Clin Cosmet Investig Dent. 2013. PMID: 24009432 Free PMC article.
-
Tissue-supported dental implant prosthesis (overdenture): the search for the ideal protocol. A literature review.Ann Stomatol (Roma). 2012 Jan;3(1):2-10. Epub 2012 May 3. Ann Stomatol (Roma). 2012. PMID: 22783448 Free PMC article.
MeSH terms
Substances
LinkOut - more resources
Full Text Sources