Clinical Trial
. 2003 Oct;30(10):1330-7.
doi: 10.1007/s00259-003-1231-0. Epub 2003 Jun 28.

Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction

Affiliations
Clinical Trial

Comparison of 16-frame and 8-frame gated SPET imaging for determination of left ventricular volumes and ejection fraction

Sachin M Navare et al. Eur J Nucl Med Mol Imaging. 2003 Oct.

Abstract

Electrocardiographic (ECG) gated single-photon emission tomography (SPET) allows for simultaneous assessment of myocardial perfusion and left ventricular (LV) function. Presently 8-frame per cardiac cycle ECG gating of SPET images is standard. The aim of this study was to compare the effect of 8-frame and 16-frame gated SPET on measurements of LV volumes and to evaluate the effects of the presence of myocardial perfusion defects and of radiotracer dose administered on the calculation of LV volumes. A total of 86 patients underwent technetium-99m SPET myocardial perfusion imaging using 16-frame per cardiac cycle acquisition. Eight-frame gated SPET images were generated by summation of contiguous frames. Left ventricular end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were calculated from the 16-frame and 8-frame data sets. The patients were divided into groups according to the administered dose of the radiotracer and the size of the perfusion defect. Results. Sixteen frame per cardiac cycle acquisition resulted in significantly larger EDV (122+/-72 ml vs 115+/-68 ml, P<0.0001), smaller ESV (64+/-58.6 ml vs 67.6+/-59.5 ml, P<0.0001), and higher LVEF (55.3%+/-18% vs 49%+/-17.4%, P<0.0001) as compared to 8-frame SPET imaging. This effect was seen regardless of whether a high or a low dose was administered and whether or not significant perfusion defects were present. This study shows that EDV, ESV and LVEF determined by 16-frame gated SPET are significantly different from those determined by 8-frame gated SPET. The radiotracer dose and perfusion defects do not affect estimation of LV parameters by 16-frame gated SPET.

PubMed Disclaimer

References

    1. J Nucl Med. 1994 Jul;35(7):1185-92 - PubMed
    1. Circulation. 1994 Dec;90(6):2899-904 - PubMed
    1. J Nucl Med. 1997 Jan;38(1):53-7 - PubMed
    1. J Nucl Cardiol. 1998 May-Jun;5(3):295-303 - PubMed
    1. Circulation. 1987 Jul;76(1):44-51 - PubMed

LinkOut - more resources