Preoperative comparison of different noninvasive strategies for predicting improvement in left ventricular function after coronary artery bypass grafting

Affiliations
Comparative Study

Preoperative comparison of different noninvasive strategies for predicting improvement in left ventricular function after coronary artery bypass grafting

Jeroen J Bax et al. Am J Cardiol. .

Abstract

Thallium-201 (Tl-201) imaging and dobutamine stress echocardiography (DSE) are the most frequently used tests in the clinical setting for assessing viability. However, Tl-201 has a suboptimal specificity and DSE a suboptimal sensitivity to predict functional improvement after revascularization. F18-fluorodeoxyglucose (FDG) imaging is considered highly accurate, but availability is limited. Sequential imaging of Tl-201 and DSE may improve accuracy for assessing viability and may be comparable to FDG. Forty-seven patients with ischemic cardiomyopathy underwent Tl-201 single-photon emission computed tomography (SPECT) at rest (4-hour delayed imaging), DSE, and FDG SPECT before bypass surgery. Sensitivity, specificity, and accuracy of 2 sequential strategies were compared with those of FDG SPECT. Strategy 1 considered Tl-201 imaging as the first step, followed by DSE in patients with an intermediate likelihood of viability on Tl-201. Strategy 2 considered DSE as the first step, followed by Tl-201 imaging. Left ventricular ejection fraction was assessed before and 6 months after revascularization, and improvement of >/=5% was considered significant. Tl-201 had a high sensitivity (95%, p <0.05 vs DSE) with a low specificity (57%, p <0.05 vs DSE). DSE had a low sensitivity (63%, p <0.05 vs Tl-201) with a high specificity (89%, p <0.05 vs Tl-201). Both strategies 1 and 2 resulted in high sensitivities (89% and 89%, respectively) and high specificities (89% and 86%, respectively), compared with FDG SPECT (sensitivity 89%, specificity 86%). Sequential testing by Tl-201 SPECT and DSE has a comparable accuracy to FDG SPECT to predict improvement in left ventricular ejection fraction after revascularization. In centers without access to FDG, sequential imaging with Tl-201 and DSE offers an accurate alternative for assessing myocardial viability.