Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 Jun;29(6):1152-8.
doi: 10.1016/s0886-3350(03)00062-2.

Six-year follow-up of laser in situ keratomileusis for moderate and extreme myopia using a first-generation excimer laser and microkeratome

Affiliations

Six-year follow-up of laser in situ keratomileusis for moderate and extreme myopia using a first-generation excimer laser and microkeratome

Walter Sekundo et al. J Cataract Refract Surg. 2003 Jun.

Abstract

Purpose: To evaluate objectively and subjectively the long-term outcome of laser in situ keratomileusis (LASIK) in patients with high and very high myopia.

Setting: Department of Ophthalmology, Philipps University, Marburg, Germany.

Methods: Thirty-three eyes of 19 patients were followed for a mean of 76 months (range 50 to 84 months) after primary LASIK using the Keratom I excimer laser (Schwind) and the ALK microkeratome (Chiron). Refraction, glare, pachymetry, corneal topography, and tear-film secretion and stability were measured. At the last examination, patients also answered a 14-item questionnaire.

Results: Preoperatively, the mean spherical equivalent was -13.65 diopters (D). At 1 year, it was -0.25 D and after 6 years, -0.88 D. Fifteen percent of eyes lost > or =2 lines of best spectacle-corrected visual acuity (BSCVA), and 9% gained > or =2 Snellen lines. At the end of the study, 46% of eyes were within +/-1.0 D of the attempted corrected and 88% were within +/-3.0 D. There were 5 microkeratome-associated complications; 3 resulted in loss of BSCVA. The latest pachymetry showed a mean corneal thickness of 498.5 microm (range 396 to 552 microm). There were no cases of keratectasia. Seventy-five percent of patients noted an increase in their quality of life. Seventy-one percent were satisfied with their postoperative visual acuity; however, 75% noticed glare and halos at night.

Conclusions: Laser in situ keratomileusis correction of very high myopia did not cause keratectasia in the long term provided the corneal thickness was respected. A flap thickness setting of 130 microm with a first-generation microkeratome resulted in a high number of cut failures. Most patients were happy with the results despite a modest level of accuracy and glare.

PubMed Disclaimer

MeSH terms

LinkOut - more resources