Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Clinical Trial
. 2003 Sep;90(1-2):131-7.
doi: 10.1007/s00421-003-0901-8. Epub 2003 Jul 8.

Beat-to-beat noninvasive stroke volume from arterial pressure and Doppler ultrasound

Affiliations
Clinical Trial

Beat-to-beat noninvasive stroke volume from arterial pressure and Doppler ultrasound

Johannes J van Lieshout et al. Eur J Appl Physiol. 2003 Sep.

Abstract

The proper understanding of the cardiovascular mechanisms involved in complaints of short-lasting dizziness and the evaluation of unexplained recurrent syncope requires continuous monitoring of cardiac stroke volume (SV) in addition to blood pressure and heart rate. The primary aim of the present study was to evaluate a pulse wave analysis method that calculates beat-to-beat flow from non-invasive arterial pressure by simulating a non-linear, time-varying model of human aortic input impedance (Modelflow; MF), by comparing MF stroke volume (SV(MF)) to Doppler ultrasound (US) flow velocity SV (SV(US)). A second purpose was to compare the two methods under two different conditions: the supine and head-up tilt (30 degrees ) position. SV(US) and SV(MF) with non-invasive arterial pressure (Finapres) as input to the aortic model were measured beat-to-beat during spontaneous supine breathing and in the passive 30 degrees head-up tilt (HUT30) position in six normotensive healthy humans [three females, mean age 24 (21-26) years]. There were variations in supine SV track between the two methods with zero difference and a SD of the beat-to-beat difference (MF-US) of 4.2%. HUT30 induced a systematic difference of 10.5% and an increase in SD to 6.9%, which was reproducible. Beat-to-beat changes in SV in the supine resting condition were equally well assessed by both methods. Systematic differences appear during HUT30 and show opposite signs. The difference between the two methods upon a change in body position may be attributed to limitations in each method.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Acta Anaesthesiol Scand. 1995 Feb;39(2):245-51 - PubMed
    1. J Appl Physiol (1985). 2003 Mar;94(3):833-48 - PubMed
    1. Stroke. 2000 Jul;31(7):1608-14 - PubMed
    1. Acta Anaesthesiol Scand. 1990 Oct;34(7):519-22 - PubMed
    1. Eur Heart J. 1995 Nov;16(11):1641-54 - PubMed

Publication types

LinkOut - more resources