Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 Nov;95(5):1901-7.
doi: 10.1152/japplphysiol.00024.2003. Epub 2003 Jul 11.

The maximally attainable VO2 during exercise in humans: the peak vs. maximum issue

Affiliations
Free article

The maximally attainable VO2 during exercise in humans: the peak vs. maximum issue

J R Day et al. J Appl Physiol (1985). 2003 Nov.
Free article

Abstract

The quantification of maximum oxygen uptake (V(O2 max)), a parameter characterizing the effective integration of the neural, cardiopulmonary, and metabolic systems, requires oxygen uptake (VO2) to attain a plateau. We were interested in whether a VO2 plateau was consistently manifest during maximal incremental ramp cycle ergometry and also in ascertaining the relationship between this peak VO2 (V(O2 peak)) and that determined from one, or several, maximal constant-load tests. Ventilatory and pulmonary gas-exchange variables were measured breath by breath with a turbine and mass spectrometer. On average, V(O2 peak) [3.51 +/- 0.8 (SD) l/min] for the ramp test did not differ from that extrapolated from the linear phase of the response in 71 subjects. In 12 of these subjects, the V(O2 peak) was less than the extrapolated value by 0.1-0.4 l/min (i.e., a "plateau"), and in 19 subjects, V(O2 peak) was higher by 0.05-0.4 l/min. In the remaining 40 subjects, we could not discriminate a difference. The V(O2 peak) from the incremental test also did not differ from that of a single maximum constant-load test in 38 subjects or from the V(O2 max) in 6 subjects who undertook a range of progressively greater discontinuous constant-load tests. A plateau in the actual VO2 response is therefore not an obligatory consequence of incremental exercise. Because the peak value attained was not different from the plateau in the plot of VO2 vs. work rate (for the constant-load tests), the V(O2 peak) attained on a maximum-effort incremental test is likely to be a valid index of V(O2 max), despite no evidence of a plateau in the data themselves. However, without additional tests, one cannot be certain.

PubMed Disclaimer

Publication types