[Comparison of conventional enteroclysis, intestinal ultrasound and MRI-enteroclysis for determining changes in the small intestine and complications in patients with Crohn's disease]
- PMID: 12858235
- DOI: 10.1055/s-2003-40547
[Comparison of conventional enteroclysis, intestinal ultrasound and MRI-enteroclysis for determining changes in the small intestine and complications in patients with Crohn's disease]
Abstract
Background: Enteroclysis, intestinal wall ultrasound (IWU) and abdominal magnetic resonance imaging (MRI) are three established methods in the diagnosis of Crohn's disease (CD). To date, however, the three methods have not been compared in one patient collective.
Aims: The present prospective study compared the relative performance of IWU, MRI and enteroclysis in determining the extent of disease involvement and intestinal complications in patients with CD both at initial diagnosis and during follow-up.
Patients and methods: Included in the present study were 48 patients with confirmed CD (age: 19-66 years) examined with all three methods between August 1999 and December 2000. IWU was performed in B-mode with a 4-7 MHz convex transducer head and a 5-12 MHz linear transducer head by an experienced examiner. At MRI, T1 and T2 weighted sequenced (Flash 2D before and after intravenous application of gadolinium DTPA or TSE) were acquired in coronal and transverse planes. Enteroclysis was performed using conventional biphasic technique. Interpretation was conducted on the basis of a standardized catalogue of findings.
Results: Changes in bowel segments consistent with inflammation were identified in 41 of 48 patients. All three methods returned equivalent findings with regard to the length of inflamed bowel segments (IWU, range: 3-25 cm, mean: 12 cm; MRI, range: 3-25 cm, mean: 10 cm; enteroclysis, range: 3-30 cm, mean: 11 cm) and wall thickness (IWU, range: 4-10 mm, mean: 7 mm; MRI, range: 5-10 mm, mean: 7 mm; of nine patients with stenotic change, five were correctly diagnosed with IWU (sensitivity, 55.6%; specificity, 97.4%), four with MRI (sensitivity, 44.4%; specificity, 100%) and six with enteroclysis (sensitivity, 66.7%; specificity, 100%). Fistulae were correctly identified in five patients with IWU (sensitivity, 55.6%; specificity, 97.4%), in four with MRI (sensitivity, 44.4%; specificity, 100%) and in six with enteroclysis (sensitivity, 66.7%; specificity, 100 %) of a total of nine patients with confirmed fistula formation. Abscesses were correctly identified in five patients with IWU (specificity, 66.7%; specificity, 100%), in five with MRI (sensitivity, 83.3%; specificity, 100%) and in no patients with enteroclysis (sensitivity, 0%; specificity, 100%) in six patients with abscesses.
Conclusion: Both IWU and MRI identify extent, severity and intestinal complications with adequate diagnostic accuracy in patients with CD. Both techniques possess the potential for replacing enteroclysis in the work-up of CD. Enteroclysis should be reserved for the work-up of complex fistula systems.
Similar articles
-
Accuracy of small-intestine contrast ultrasonography, compared with computed tomography enteroclysis, in characterizing lesions in patients with Crohn's disease.Clin Gastroenterol Hepatol. 2013 Aug;11(8):950-5. doi: 10.1016/j.cgh.2013.01.015. Epub 2013 Jan 29. Clin Gastroenterol Hepatol. 2013. PMID: 23375998
-
MRI in the diagnosis of small bowel disease: use of positive and negative oral contrast media in combination with enteroclysis.Eur Radiol. 2000;10(9):1377-82. doi: 10.1007/s003300000354. Eur Radiol. 2000. PMID: 10997423 Clinical Trial.
-
Magnetic Resonance Enteroclysis imaging of Crohn's.Radiol Med. 2005 Sep;110(3):221-33. Radiol Med. 2005. PMID: 16200044 English, Italian.
-
Magnetic resonance imaging evaluation of small intestinal Crohn's disease.Best Pract Res Clin Gastroenterol. 2006 Feb;20(1):137-56. doi: 10.1016/j.bpg.2005.09.002. Best Pract Res Clin Gastroenterol. 2006. PMID: 16473805 Review.
-
Magnetic resonance enteroclysis compared with conventional enteroclysis and computed tomography enteroclysis: a critically appraised topic.Abdom Imaging. 2008 Jan-Feb;33(1):34-7. doi: 10.1007/s00261-007-9308-z. Abdom Imaging. 2008. PMID: 17874264 Review.
Cited by
-
Comparison of sonographically measured bowel wall vascularity, histology, and disease activity in Crohn's disease.Eur Radiol. 2009 Jun;19(6):1379-86. doi: 10.1007/s00330-008-1290-5. Epub 2009 Jan 30. Eur Radiol. 2009. PMID: 19184036
-
Assessment of inflammatory activity in Crohn's disease by means of dynamic contrast-enhanced MRI.Radiol Med. 2007 Sep;112(6):798-809. doi: 10.1007/s11547-007-0192-y. Epub 2007 Sep 20. Radiol Med. 2007. PMID: 17885739 English, Italian.
-
Comparison of high-resolution ultrasound and MR-enterography in patients with inflammatory bowel disease.World J Gastroenterol. 2011 Feb 28;17(8):1018-25. doi: 10.3748/wjg.v17.i8.1018. World J Gastroenterol. 2011. PMID: 21448353 Free PMC article.
Publication types
MeSH terms
Substances
LinkOut - more resources