Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2003 Jul;33(7):992-8.
doi: 10.1046/j.1365-2222.2003.01700.x.

ELISpot: a new tool for the detection of nickel sensitization

Affiliations

ELISpot: a new tool for the detection of nickel sensitization

M Lindemann et al. Clin Exp Allergy. 2003 Jul.

Abstract

Background: The standard assay for the clinical detection of contact allergy against nickel is the patch test. For research purposes, the in vitro lymphocyte transformation test (LTT) is mostly applied. However, the in vivo application of allergens includes the potential of sensitization, whereas the LTT demands 6 days of cell culture and radioactive labelling procedures.

Objective: The purpose of this study was to validate an enzyme-linked immunospot (ELISpot) assay to specifically detect cellular response against nickel sulphate in correlation with patch test, anamnestic data, and LTT results.

Methods: In probands with positive (n=60) and negative patch test results (n=19), cytokine ELISpot and LTT were performed in parallel using various concentrations of nickel sulphate, various numbers of responding peripheral blood mononuclear cells (PBMC), and various durations of cell cultures.

Results: Concentrations of 50 and 75 microM nickel sulphate were found to be optimal to stimulate in the ELISpot 4x10(5) and in the LTT 2x10(5) PBMC, respectively. An increase in ELISpot sensitivity was reached by pre-incubation with nickel sulphate for 24 h prior to transfer to ELISpot plates. In nickel-sensitive probands, an average precursor cell frequency of 19x10(5), 1.7x10(5), and 0.7x10(5) could be defined for IFN-gamma, IL-2, and IL-4 producing PBMC, respectively. In non-sensitive probands IFN-gamma producing cells were detectable, but with significantly lower frequency (2x10(5); P=0.004). The prior performance of patch tests had no significant effect on cytokine production or lymphocyte proliferation. Overall, the parameters patch test, anamnestic nickel allergy, ELISpot, and LTT results were positively correlated (P<0.05).

Conclusions: Based on these experiments, the quantitative in vitro detection of cell-mediated reactions towards nickel as well as other heavy metal ions should be possible utilizing the above-described ELISpot assay.

PubMed Disclaimer

Publication types